User manual

3.2.2 Camera Startup Sequence
As soon as the camera's power supply has been established, the two LEDs will
show the progress of the startup sequence (see section5.4.3,
LED Signals and LED
Configuration
, in the
Software Manual
).
Booting: Immediately after connecting the power supply, the red LED lights
up, blinks for two seconds, then stays on permanently. The camera's boot
loader checks the hardware, unpacks and starts the operating system. Next,
the camera checks its operating system for errors. In case of an error, the
camera will start using the backup operating system. After that, both LEDs
light up for four seconds.
Waiting for key pressed: Both LEDs light up for four seconds. If you press the
"R" or "L" key of the camera during this time, the camera will execute the
corresponding function (see sections 3.3.5 and 3.3.6).
Ready: Once the camera software has been started, the green LED is on per-
manently and the red LED blinks. You can now reach the camera via the net-
work using a browser.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
75/112
Q22M Camera Manual Part 1
1) Start
2) Key?
3) Ready
Note
During the startup sequence of the camera, the LEDs will always light
up, even if they have been deactivated in Admin Menu> LED Setup.
LEDs (1 x green, 1 x red)
"R" key
"L" key