Technical data

114/148
S14 Camera Manual: Operating The Camera
© MOBOTIX AG • Security Vision Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
3.2.6 Starting The Camera With The Factory IP Address
Under certain circumstances, you may have to reset the camera to its factory IP address.
This could be the case, for example, if the IP address has been lost or the camera does
not respond to the last known IP address. Proceed as follows to start up the camera with
its factory IP address:
1. If the camera is powered on, disconnect the power supply by unplugging the cor-
responding cables and then reconnect the power supply.
2. Wait until both LEDs light up simultaneously for the first time.
3. Press the L key within the next four seconds and hold it down (if you need to
try again, go back to Step 1).
4. Only release the L key once the camera emits a single sound (”boing”).
Notes
If you use the camera’s L key to load the factory network configuration, this configu-
ration is not automatically saved in the camera’s flash memory. When the camera
is next rebooted without using the L key, the last stored network configuration will
be used. To permanently store the new network configuration in the camera’s flash
memory, open Admin Menu> Store.
As opposed to resetting the camera using Admin Menu> Reset configuration to
factory defaults, the user information will not be reset if the camera is booted using
the factory IP address.
Passwords and cam-
era settings will
not be changed
R L
Make sure you store
the default network
conguration to the
permanent ash memory