User manual
2.8 Indoor/Outdoor Mounting Instructions
2.8.1 Mounting Indoor Cameras to a Wall or Ceiling
In order to mount the MOBOTIX D12 to a ceiling or wall, you need to drill the holes
for the fixtures. Use the supplied
drilling template
to mark the position of the holes
for the fixtures and the holes through which the cables will be led later on (fold-
out). Remember to position the drilling template according to the direction of
the camera's PIR sensor.
Planning and Connecting the CAT5 Cable
(1) Position the camera housing over the cable exit.
(2) Lead the cables through the appropriate holes in the housing.
(3) Properly lead the cable(s) through the cable guides at the outer rim of the
housing.
(4) Use the proper screws to mount the camera housing to the wall or ceiling.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
52/132
D12 Camera Manual Part 1
Please also observe the
general hints in section
2.15 on mounting the
camera to different sur-
faces!
Find the folded drilling
templates at the end of
the manual!
Make sure that the drill-
ing template is not scaled
down when printing!
Max. torque for all
screws: 4Nm
(2.95lbf ft)
Note
Make sure that the cable length is appropriate.
Check the following figure to see how the cables
are running properly. Cable length should be
50cm (20in) when mounting the D12 and 70cm
(28in) when mounting the D12 with Outdoor wall
mount, always measured from the wall. There are
two ways to accommodate cable that is too long
(see figures):
(1) Loop near the RJ45
connectors
(2) Loop beneath the cam-
era
(1)
(2)
120°
R=75 mm/3 in
120°
120°