Safety Instructions

Installation
14
Connecting as a standalone
AE-M can be connected to the door lock, door button, and door sensor directly without connecting a separate I/O device.
NOTE
AE-M can be used as a multi-door controller with the slave devices with the RS485 cable. The slave devices are used as dummy
readers and authentication is performed in the master device.
If AE-M is connected as the master device, only card authentication is available on the slave device.
Up to 31 slave devices can be connected.
For more information, contact the MOCA System technical support team (mocainc.zendesk.com).
AE-M
PC
Relay
Door sensor
Door button
DC
power
DC
power
Deadbolt /
Door strike
Hub
Fail Safe Lock
Fail Secure Lock
or
Power
TTL connection
15 - TTL IN 0 Purple
16 - TTL IN 1 Brown
17 - TTL GND Gray
Relay connection
18 - RLY NO Gray (White stripe)
19 - RLY COM Green (White stripe)
20 - RLY NC Orange (White stripe)
Power supply connection
21 - PWR +VDC Red
22 - PWR GND Black (White stripe)