User`s manual
List window
7-132  ModelSim XE Graphic Interface ModelSim Xilinx User’s Manual
The Triggers page includes the following options:
• Deltas:Expand Deltas
When selected with the Trigger on: Signals check box, displays a new line for 
each time step on which items change, including deltas within a single unit of 
time resolution.
• Deltas:Collapse Deltas 
Displays only the final value for each time unit in the List window.
• Deltas:No Deltas 
No simulation cycle (delta) column is displayed in the List window.
• Trigger On: Signals
Triggers on signal changes. Defaults to all signals. Individual signals may be 
excluded from triggering by using the Prop > Signals Props dialog box or by 
originally adding them with the -notrigger option to the add list command 
(CR-
19)
.
• Trigger On: Strobe 
Triggers on the Strobe Period you specify; specify the first strobe with First 
Strobe at:.
• On Duration
The duration for gating to remain open after the last list row in which the 
expression evaluates to true; expressed in x number of default timescale units. 
Gating is level-sensitive rather than edge-triggered.