PRE-U SE INSTR UCTIONS
5
!
WARNING Before using this outdoor fire table, make sure
you have read, understand and are following all information
provi ded in the Important Safety Information section of this
manual . Failure to follow those instructions can cause death,
serious injury or property damage.
Prior to each gas fire place operation, check the hose and valve fo r evidence of
excessive abr asion or wear though the visual check hole on the side of the
base. Replace visual che ck cap prior to operating fireplace.
BURNER CONNECTIONS
Make sure the regulator valve and hose connections are securely fastened to
the bur ner and t he t ank. If your unit was assembled for you, visually check t he
connection between the burner pipe and orifice. Make sure the burner
pipe fits over the orifice.
!
WARNING Failure to inspect this connection or follow
these instr uctions could cause a fire or an explosion, which can
cause death, serious bodily injury, or damage to property
Orifi ce is located
in this connection
Please refer t o diag ram for proper installation.
If the burner pipe doe s not rest flush to the orifice please
contact Elementi a t 909 -985-5553 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, tu rn LP gas
tank to “ON” at valve.
Spray leak solution on valve connections paying
particular attention to the areas indica ted by arrows.
If any bubbles app ear turn LP gas tank OFF, reconnect
and re-test. If you continue to see bubbles after several
attempts, disconnect LP gas source a nd contact
Elementi at 909-985-5553 for assistance.
If no bubbles app ear after one minute turn tank OFF,
wipe away solution and pr oceed.
Check for leaks at these locations