Installation Guide

14 FR-W1916-56L
FIG. 11
White (neutral)
Outlet Box
Black (hot)
Black (“AC IN L”)
Red (to motor)
Gray (to motor)
Yellow (to motor)
Yellow (motor)
Gray (motor)
Red (motor)
Receiver
Green (Ground)
To hanger ball
Green (Ground)
To hanger bracket
Green (Ground)
White (for light)
White (for light)
Blue (for light)
Blue (for light)
White (“AC IN N”)
Green (ground)
Motor to receiver electrical connections: (FIG.11)
1. Connect the hanger ball/downrod assembly ground wire,
mounting bracket ground wire and receiver ground wire to
the ground wire in the ceiling outlet box.
WARNING: Failure to connect ground wires could result in poor
fan control functionality.
2. Connect the red wire from the fan to the red wire marked
“TO MOTOR” from the receiver.
3. Connect the gray wire from the fan to the gray wire marked
“TO MOTOR” from the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked
“TO MOTOR” from the receiver.
5. Connect the white wire from the fan to the white wire marked
‘FOR LIGHT” from the receiver.
6. Connect the black wire from the fan to the black wire marked
“FOR LIGHT” from the receiver.
Receiver to house supply wires electrical connections (FIG.11):
1. Connect the black (hot) wire from the ceiling outlet box to
the black wire marked “AC in L” from the receiver.
2. Connect the white (neutral) wire from the ceiling outlet box
to the white wire marked “AC in N” from the receiver.
WARNING: Check to see that all connections are tight, including
ground, and that no bare wires are visible at the plastic wire nuts
except for the ground wire.
9. Making the Electrical Connections (cont.)