Assembly and Installation

11FH-W1803
7. MAKING THE ELECTRICAL CONNECTIONS (cont.)
Receiver
White (neutral)
Outlet Box
White (“AC IN N”)
Black (“AC IN L”)
Black (hot)
Trim Ring
Motor
Safety
Cable
Wood
Screw
Green (Ground)
Green (Ground)
from hanger ball
Green (Ground)
from hanger
bracket
Green (Ground)
from receiver
Receiver to house supply wires electrical connections:
(Fig. 9 &10)
1. Lift motor assembly and hang it on the hook of mounting bracket
using one of the screw holes. (Fig. 9)
2. Secure the safety cable to the building structure using a wood
screw (not included). (Fig. 9)
3. Connect the fan assembly ground wire, mounting bracket ground
wire and receiver ground wire to the ground wire in outlet box.
(Fig. 10)
WARNING: Failure to connect ground wires could result in poor
fan control functionality .
4. Connect the black (hot) wire from the ceiling to the black wire
marked “AC in L” from the receiver. (Fig. 10)
5. Connect the white (neutral) from the ceiling to the white wire
marked “AC in N” from the receiver. (Fig. 10)