Data Sheet
Sensor Documentation         Modern Robotics, Inc. 
Version 1.4.3    27 
Register 
Function 
0x00 
Sensor Firmware Revision 
0x01 
Manufacturer Code 
0x02 
Sensor ID Code 
0x03 
Not Used 
0x04 
Sound Level 
0x05/0x06 
Pitch (lsb/msb) 
0x07 
Duration 
The order if the 4 control bytes, Sound Level, Pitch low, Pitch high and Duration are 
arranged such that a signal 4 byte write can be used to initiate a tone. 
Sound Level: 
Controls the amplitude of the output signal from 0 to 3 where 0 is the quietest and 3 is 
the loudest. 
Pitch: 
Consisting of 2 bytes to make a word, the Pitch controls the frequency of the output in 
increments of 1Hz. The frequencies range from 1Hz to 65kHz, although operation over 
5kHz is not recommended and may damage the device. The speaker resonates at about 
2kHz, so the speaker will sound much louder at this frequency. 
Duration: 
This controls the duration of the tone in increments of 10mS. The duration of the tone 
can range from 10mS – 2.55S. The duration of the tone begins a countdown and will 
stop when the counter reaches 0. The duration may be updated at anytime to extend 
the length of a tone past 2.55S. 