® GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS MODEL HD MODEL HDB MODEL HD MODEL PDP MODEL HDB MODEL BDP MODEL PTP/BTP 6-189.
TABLE OF CONTENTS Modine’s power vented unit heaters are designed for the heating requirements of commercial and industrial buildings with select models available for residential garage heating as well. For locations where negative pressure may be an issue or energy savings over older gravity vented units may be desired, Modine power vented gas fired unit heaters are your solution.
DESIGN FEATURES - ALL UNITS Tubular Heat Exchanger Power Vented Unit Heaters, 30-125MBH For residential, commercial or industrial applications that require a low profile unit, Modine offers the Hot Dawg®. Capable of being installed just one inch below the ceiling, the superior quality of the Hot Dawg makes it a preferred choice for a variety of applications, including garages and workshops. Figure 3.
DESIGN FEATURES - MODELS HD/HDB Figure 4.1 - Factory Mounted Standard and Optional Features (Models HD/HDB) m o s q k j l r n j Power Exhauster (STD) All HD series (low profile) unit heaters are supplied with a round vent pipe connection. k Pressure Switch (STD) An automatic reset vent pressure switch is supplied on all HD series (low profile)unit heaters and is designed to prevent operation of the main burner in the event there is restricted venting of flue products.
DESIGN FEATURES - MODELS PDP/BDP Figure 5.1 - Factory Mounted Standard and Optional Features (Models PDP/BDP) r s p k q nl o m j All units include the standard (STD) features, and may include the optional (OPT) features shown. j Gas Valve (See Table 18.2) a) Single Stage Gas Valve - (STD) The main gas valve is factory installed on the unit heater gas train. The main gas valve provides the pilot, regulator, main gas, and manual shutoff functions.
DESIGN FEATURES - MODELS PTP & BTP Figure 6.1 - Factory Mounted Standard and Optional Features (Model PTP) 6 8 10 1 9 2 5 4 3 7 j Power Exhauster (STD) All PTP series unit heaters are supplied with a round vent pipe connection. k Pressure Switch (STD) An automatic reset vent pressure switch is supplied on all PTP series unit heaters and is designed to prevent operation of the main burner in the event there is restricted venting of flue products.
GENERAL PERFORMANCE DATA - MODELS HD & PDP Table 7.
GENERAL PERFORMANCE DATA - MODEL PTP & BTP Table 8.
GENERAL PERFORMANCE DATA - MODEL PTP & BTP Table 9.1 - Blower Model BTP Motor Amp Draw m n Supply Voltage Motor HP 115V/1ph 230V/1ph 208V/3ph 230V/3ph 460V/3ph 575V/3ph 1/4 3.70 - - - - - 1/3 5.00 2.50 1.60 1.40 .70 0.60 1/2 7.20 3.60 2.10 2.20 1.10 0.80 1 12.00 6.00 3.20 3.20 1.60 1.30 1-1/2 15.00 7.50 4.60 4.80 2.40 1.90 2 - - 6.00 5.80 2.90 2.30 3 - - 8.40 7.80 3.90 3.20 5 - - 13.60 12.30 6.20 5.10 Table 9.
BLOWER PERFORMANCE DATA - MODEL BTP Table 10.
BLOWER PERFORMANCE DATA - MODEL BTP Table 11.1 - Blower Model BTP 150-250 (40-55°F temp rise for 250 size unit) j k l External Static Pressure (“W.C.) 0.0 Model Size ATR CFM 40 2778 45 2469 HP 1 1/2 1 55 2222 2020 150 60 1852 70 40 1709 1587 3241 45 2881 50 2593 60 65 70 2160 1994 1852 1.0 229 5.0 1 - 1/4 45 3704 3292 2963 2469 4630 250 50 55 4115 3704 3367 - - 230 2.5 232 5.0 175 4.0 - - - - 229 3.0 - 175 - - 232 3.5 565 699 650 175 2.
BLOWER PERFORMANCE DATA - MODEL BTP Table 12.1 - Blower Model BTP 250-400 (60-70°F temp rise for 250 size unit) j k l External Static Pressure ("W.C.) 0.0 Model Size ATR CFM HP 250 65 70 3086 2849 2646 1 1-1/2 360 5556 45 4938 50 4444 3704 40 45 6481 5761 5185 4321 - 490 241 3.0 - - 530 241 2.0 23 5.0 566 241 1.5 23 4.0 601 - - 241 0.5 23 3.0 180 4.5 635 - 2.5 2 1.0 - - - - - - - - 1/2 3.5 241 2.5 241 1.5 241 1.0 241 0.
GENERAL PERFORMANCE DATA - MODELS HDB & BDP Table 13.
BLOWER PERFORMANCE DATA - MODEL HDB Table 14.1 - Power Code Description - HDB Models Power Code 01 Unit Voltage 115/60/1 HDB60 HDB75 HDB100 HDB125 1/4 HP 1/3 HP 1/2 HP 1/2 HP Blower Speed Curves Models (HDB 60-125) Low HDB 60 60 741 55 808 50 889 45 988 40 1111 35 0.00 Temperature Rise (Deg. F) 684 1270 0.10 0.20 0.30 0.40 0.50 0.60 65 1140 60 1235 55 1347 50 1481 45 1646 40 1852 35 0.00 0.70 2116 0.10 0.20 External Static Pressure (IN. WC) 0.50 0.60 0.70 0.
BLOWER PERFORMANCE DATA - MODEL BDP Table 15.
BLOWER PERFORMANCE DATA - MODEL BDP Table 16.1 - Models With or Without Blower Enclosure - Blower Model BDP j k Model Size 150 175 200 250 300 350 400 ATR CFM 0.0” Static Press. RPM HP Drive Turns 0.1” Static Press. RPM HP Drive Turns 0.2” Static Press. RPM HP Drive Turns 0.3” Static Press. RPM HP Drive Turns 0.4” Static Press. RPM HP Drive Turns 40 2778 515 1/2 4.0 565 3/4 38 4.5 615 4.0 665 3.0 705 45 2469 455 1/3 0.0 515 1/2 96 4.0 570 3.0 620 3.
BLOWER PERFORMANCE DATA - MODEL BDP Table 17.1 - Models With or Without Blower Enclosure - Blower Model BDP j k Model Size 150 175 200 250 300 350 400 Data for use with filters only ATR CFM 0.5” Static Press. RPM HP Drive Turns 40 2778 750 45 2469 715 50 2222 685 55 2020 665 60 1852 650 65 1709 640 70 1587 630 40 3241 970 2 45 2881 900 1-1/2 50 2593 845 55 2357 805 60 2160 770 65 1994 745 3.0 830 70 1852 725 1/2 96 0.0 770 3.
GAS CONTROL DATA - ALL MODELS Table 18.
ACCESSORIES Table 19.1 - Field Installed Accessories Model Controls Cabinet and Air Mover Feature HD HDB PDP BDP PTP BTP Vertical Deflector Blades - Allows directional discharge air control in the left and right directions. • • • • • • Downward Air Deflector Hoods - Available in 30°, 60°, and 90° configurations these deflector hoods enable the unit to be mounted higher while still providing heat to the building occupants. Refer to page 16 for further details.
PERFORMANCE DATA - HOODS FOR PROPELLER MODELS Table 20.
PERFORMANCE DATA - HOODS FOR BTP BLOWER MODELS Table 21.
PERFORMANCE DATA - VELOCITY GENERATING NOZZLES Figure 22.1 - Velocity Generating Nozzles 40° DOWNWARD NOZZLE j H T S 90° VERTICAL NOZZLE H S S 5-WAY NOZZLES T 40° SPLITTER NOZZLE T S H S S j Velocity generating nozzles available for Blower Model BDP only. Table 22.1 - Blower Unit Model BDP Velocity Generating Nozzle Performance Data (feet) BDP Blower Model Size Nozzle Type 40° Downward Nozzle 90° Vertical Nozzle 40° Splitter Nozzle 5-Way Nozzle Max. Mounting Ht. (ft.) Heat Throw (ft.
UNIT SELECTION Selection Procedure In order to properly select a unit heater it is necessary to have the following basic information. 1. Heating output capacity Model size output is to be matched against the heat loss to be replaced. 2. External static pressure (blower units only) The external static pressure (E.S.P.) is determined using the ASHRAE Guide for duct losses or provided by the design engineer. 3. Accessory internal static pressure (Nozzles, transitions, filters, etc.
UNIT SELECTION Selection Example Conditions (Blower Unit) In the following example, select a unit heater to meet the following conditions: 1. Heating output capacity = 156,000 Btu/Hr per design engineer 2. External Static Pressure = 0.2. 3. Internal Static Pressure = 0.0. No static producing accessories are required 4. Heat exchanger and burner = Aluminized Steel 5. Gas Type = Propane 6. Gas Controls = Two stage Intermittent Pilot 7. Supply Voltage: 230V/60Hz/3Ph 8. Altitude: 1,000 feet 9.
DIMENSIONAL DATA - MODEL HD/HDB Propeller Units - Model HD Blower Units - Model HDB Figure 25.1 - Dimensional Drawings - Model HD Figure 25.2 - Dimensional Drawings - Model HDB 3/8"-163/8"-16 MOUNTING HOLESHOLES 14.9" BETWEEN MOUNTING MOUNTING HOLESHOLES TYP TYP14.9" BETWEEN MOUNTING (MODEL SIZES 100 AND 125 ONLY) (MODEL SIZES 100 AND 125 ONLY) 3/8 x 1"3/8 LONG x 1" LONG G G 3.5" 14.9" BETWEEN 3/8"-163/8"-16 MOUNTING HOLESHOLES 14.
DIMENSIONAL DATA - MODEL PDP Propeller Units - Model PDP Figure 26.1 - Dimensional Drawings C A H M F W K AA X CC DD G J E B K LL BB EE L (M IN. DI STAN C E TO W ALL) D (OPENING) Table 26.1 - Dimensions (inches) - PDP j Dimension Symbol A B C D E F G H Jk K (Mounting Holes) l Lm M W X AA BB CC DD EE LL Gas Connections n Fan Diameter Approx.
DIMENSIONAL DATA - MODEL BDP Blower Units - Model BDP Figure 27.1 - Dimensional Drawings C A F H W K DD X CC J EE DD CC S O G AA E N 5 9/16" P J 5 9/16" G 3/4" K B R xT Q xV BB D (OPENING ) L (MIN.D ISTAN C E TO W ALL) Table 27.
DIMENSIONAL DATA - MODEL PTP Propeller Units - Model PTP Figure 28.1 - Dimensional Drawings ADJUSTABLE LOUVERS A G 4 MOUNTING HOLES R U T POWER VENTER VENT PIPE CONNECTION S ACCESS PANEL B GAS CONNECTION E OPENING F J D OPENING I C H M (APPROX) Q (MIN DIST TO WALL) Table 28.1 - Dimensions (inches) - PTP j Models PTP150 PTP175 PTP200 PTP250 PTP300 PTP350 PTP400 A 35.53 42.53 42.53 42.53 42.53 42.53 42.53 B 23.06 25.81 25.81 31.31 31.31 39.56 39.56 C 22.05 22.
DIMENSIONAL DATA - MODEL BTP Figure 29.1 - Dimensional Drawings - Model BTP 6 MOUNTING HOLES G R ADJUSTABLE LOUVERS A BLOWER ENCLOSURE (OPTIONAL) 4 7/8" 7/8" T FILTER RACK (OPTIONAL) 4.88 U W X V S POWER VENTER VENT PIPE CONNECTION 20.53 ACCESS PANEL B OxP E OPENING L J C K D OPENING N MOTOR CORD STRAIN RELIEF M (APPROX.) I F GAS CONNECTION T-STAT CONNECTION ELECTRICAL CONNECTION H Q (MIN DIST TO WALL) Table 29.
SPECIFICATIONS - ALL MODELS General A. Standards All unit(s) shall include: A.1. ETL design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for “Gas Unit Heater and Gas-Fired Duct Furnaces” for safe operation, construction, and performance. B. Mechanical Configuration B.1. Furnace(s) section with 82% minimum efficiency provided by an indirect-fired heat exchanger with dimpled tube pattern for efficient heat transfer. (PDP/BDP models) B.2.
SPECIFICATIONS - ALL MODELS G. Air Mover J.5. G.1. The motor horsepower shall be ____. An Energy Saver Kit used to reduce stratified air in high mounting height applications. (PDP/BDP models) G.2. The motor wiring shall be in flexible metal BX conduit. J.7. Vertical Deflector Kit to enable side distribution of airflow. G.3. (opt) The motor shall be controlled by a time delay relay (opt) and motor starter. J.8.
MODEL NOMENCLATURE Figure 32.1 - Model Number Designations PDP 200 A E 01 30 B A N Factory Installed Option Digit N - None Unit Configuration HD - Tubular Power Vented Propeller Unit HDB - Tubular Power Vented Blower Unit PDP - Propeller Unit Power Vent BDP - Blower Unit Power Vent PTP - Tubular Power Vented Propeller Unit Future A - All Dev Digit MBH Input (refer to pages 7 & 9) 100 - 100,000 Btu/hr input 200 - 200,000 Btu/hr input 250 - 250,000 Btu/hr input etc.
THIS PAGE INTENTIONALLY LEFT BLANK 6-189.
THIS PAGE INTENTIONALLY LEFT BLANK 34 6-189.
THIS PAGE INTENTIONALLY LEFT BLANK 6-189.
The Modine brand has been the industry standard since Arthur B. Modine invented and patented the first lightweight, suspended hydronic unit heater in 1923. No other manufacturer can provide the combined application flexibility, technical expertise and fast delivery found at Modine. Consult your local Modine distributor for help in solving your indoor air problems.