Wiring Guide

WIRING DIAGRAMS – MODELS HD/HDB, HDS/HDC, PTS/BTS
6-461.1 7
FAN
MOTOR
P1-7
* INTEGRATED
CONT ROL
115V
PE
MOTOR
SPARK
IGNIT OR
24V
MV
P1-9P1-2
PRESSURE
P1-5P1-3
SEC
P1-6
COM
P1-4
FLAME
SENSO R
GAS
VALVE
HIGH LIMIT
THERM OSTAT
L1 IND
P1-8W
GND
L1
L2
CALL FOR HEA T
NTRL NTRL NTRL
NTRL
L1
EAC
R
FUSE
C
115V/60HZ/1Ø
UNIT CIRCUIT
CIRCUIT BREAKER
(BY OTHERS)
HIGH LIMI T
0
1
342
6 8 7
Factory 115V Unit Power
P1-7
* INTEGRATED
CONT ROL
115V
24V
MV
P1-9P1-2
PRESSURE
P1-5P1-3
SEC
P1-6
COM
P1-4
FLAME
SENSOR
GAS
VALVE
HIGH LIMIT
THERMOSTAT
P1-8
W
CALL FOR HE AT
NTRL
L1
R
FUSE
C
HIGH LIMIT
230V Fan/Blower Power Only
CONTROL CIRCUIT MUST BE 115V POW ER
PE
MOTOR
SPARK
IGNIT OR
L1 IND NTRL NTRL NTRLEAC
See note #6
for motor
connections
GND
115V/60HZ/1Ø
CONTROL CIRCUIT POW ER
FROM STEP DOWN
TRANSFORMER (BY OTHERS)
FAN
MOTOR
0
1
342
6 8 7
See note #6
for motor
connections
230V/60HZ/1Ø
FAN CIRCUIT POWER
CIRCUIT BREAKER
(BY OTHERS)
L1
L2
REFER NOTE 7
INDICATES TERMINAL
BOARD CONNECTION
SINGLE STAGE, DIRECT SPARK IGNITION,
100% SHUT-OFF, MULTIPLE RETRY W/ AUTO RESET FROM LOCKOUT
WIRING LEGEND
FACTORY WIRING
INTERNAL COMPONENT WIRING
FIELD WIRING
WIRE NUT
LINE 24V
5H080273B1 REV _
*SHOWN WITH UNITED TECHNOLOGIES
LABEL, SEE CHART FOR OTHER LABELS
147
852
369
G
W
R
C
Y
GND
O
WH
COM
L1, (BK)
R
Y
PIN 6
120
R
COM
24
R
FAN
MOTOR
Y
WH
BK
SEC
PIN 5
Y
XFMR
PRESSURE
SWITCH
PE
MOTOR
LOW VOLTAGE
THERMOSTAT
(BY OTHERS)
LIMIT
CONTROL
GAS
VALVE
115V/60HZ/1Ø
UNIT POWER
CIRCUIT BREAKER
(BY OTHERS)
FLAME
SENSOR
BL
GR, (G)
BK
L2, (WH)
L2, (WH)
N
E
U
T
R
A
L
IND
L1
L1
EAC
PARK
HONEYWELL
LABEL
SPARK
IGNITOR
UT
LABEL
IGNITION
CONTROL
COM
24VAC
N
E
U
T
R
A
L
IND
XFMR
L1
EAC/BLO
M1
PARKCOOL
LIMIT CONTROL
(SEE NOTE 5)
L1, (BK)
SWITCH
REFER
NOTE 7
1
0
687
2
4
3
L1, (BK)
L2, (BL)
230V/60HZ/
FAN CIRCUIT POWER
CIRCUIT BREAKERS
(BY OTHERS)
See note #6
for motor
connections
>Disconnect relay power leads (#2 & #6) from 115V
supply and connect 230V as shown.
>All other unit power must be 115V as shown.
>See note #6 for motor connections.
230V Fan/Blower Power Only
CONTROL CIRCUIT MUST BE 115V POWER
Factory 115V Unit Power
147
852
369
G
W
R
C
Y
GND
O
WH
COM
R
Y
PIN 6
120
R
COM
24
R
FAN
MOTOR
Y
WH
BK
SEC
PIN 5
Y
XFMR
PRESSURE
SWITCH
PE
MOTOR
LOW VOLTAGE
THERMOSTAT
(BY OTHERS)
LIMIT
CONTROL
GAS
VALVE
115V/60HZ/1Ø
CONTROL CIRCUIT POWER
FROM STEP DOWN
TRANSFORMER (BY OTHERS)
FLAME
SENSOR
BL
BK
L2, (WH)
N
E
U
T
R
A
L
IND
L1
L1
EAC
PARK
HONEYW ELL
LABEL
SPARK
IGNITOR
UT
LABEL
IGNITION
CONTROL
COM
24VAC
N
E
U
T
R
A
L
IND
XFMR
L1
EAC/BLO
M1
PARKCOOL
LIMIT CONTROL
(SEE NOTE 5)
L1, (BK)
1
0
687
2
43
See note #6
for motor
connections
5H080273B1
WIRING DIAGRAM, SINGLE STAGE, RELAY
CAUTION:
FAILURE TO WIRE THIS UNIT ACCORDING
TO THIS WIRING DIAGRAM MAY RESULT
IN INJURY TO THE INSTALLER OR USER.
FOR DEVIATIONS CONTACT THE FACTORY.
NOTES TO INSTALLER:
1. ALL WIRING MUST COMPLY WITH NATIONAL
ELECTRIC CODE AND ALL LOCAL CODES.
2. ALL COMPONENTS MUST AGREE WITH
THEIR RESPECTIVE POWER SOURCE.
3. VERIFY THE POWER SOURCE AND
THE UNIT POLARITY.
4. USE TYPE 105°C REPLACEMENT WIRE
300V OR GREATER.
5. USED ON PROPELLER MODELS 100 AND LARGER.
6. UNIT IS SHIPPED WIRED FOR 115V. WHEN
WIRING FOR 230V FOLLOW THIS DIAGRAM
AND MOTOR WIRE LABELS FOR 230V.
7. OPTIONAL UNIT DISCONNECT SWITCH
USED ON 115V UNITS ONLY.