GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS MODEL HD MODEL HDB MODEL HD MODEL PDP MODEL BDP MODEL PTP 6-189.
TABLE OF CONTENTS Modine’s power vented unit heaters are designed for the heating requirements of commercial and industrial buildings with select models available for residential garage heating as well. For locations where negative pressure may be an issue or energy savings over older gravity vented units may be desired, Modine power vented gas fired unit heaters are your solution.
DESIGN FEATURES - ALL UNITS Tubular Heat Exchanger Power Vented Unit Heaters, 30-125MBH For residential, commercial or industrial applications that require a low profile unit, Modine offers the Hot Dawg®. Capable of being installed just one inch below the ceiling, the superior quality of the Hot Dawg makes it a preferred choice for a variety of applications, including garages and workshops. Figure 2.1 - Hot Dawg Propeller Unit Heater Figure 2.
DESIGN FEATURES - MODELS HD/HDB Figure 4.1 - Factory Mounted Standard and Optional Features (Models HD/HDB) ➃ ➅ ➉ ➇ ➁ ➀ ➂ ➈ ➄ ➀ Power Exhauster (STD) All HD series (low profile) unit heaters are supplied with a round vent pipe connection. ➁ Pressure Switch (STD) An automatic reset vent pressure switch is supplied on all HD series (low profile)unit heaters and is designed to prevent operation of the main burner in the event there is restricted venting of flue products.
DESIGN FEATURES - MODELS PDP/BDP Figure 5.1 - Factory Mounted Standard and Optional Features (Models PDP/BDP) ➈ ➉ ➆ ➁ ➇ ➄➂ ➅ ➃ ➀ All units include the standard (STD) features, and may include the optional (OPT) features shown. ➀ Gas Valve (See Table 14.2) a) Single Stage Gas Valve - (STD) The main gas valve is factory installed on the unit heater gas train. The main gas valve provides the pilot, regulator, main gas, and manual shutoff functions.
DESIGN FEATURES - MODELS PTP Figure 6.1 - Factory Mounted Standard and Optional Features (Model PTP) 6 8 10 1 9 2 5 4 3 7 ➀ Power Exhauster (STD) All PTP series unit heaters are supplied with a round vent pipe connection. ➁ Pressure Switch (STD) An automatic reset vent pressure switch is supplied on all PTP series unit heaters and is designed to prevent operation of the main burner in the event there is restricted venting of flue products.
GENERAL PERFORMANCE DATA - MODELS HD & PDP Table 7.
GENERAL PERFORMANCE DATA - MODEL PTP Table 8.1 - Propeller Unit Model PTP General Performance Data Model PTP Sizes 150 175 200 250 300 350 400 Btu/Hr Input 150,000 175,000 200,000 250,000 300,000 350,000 400,000 Btu/Hr Ouput 120,000 140,000 160,000 200,000 240,000 280,000 320,000 Entering Airflow (CFM) @ 70°F 2140 2725 2870 3995 4545 5280 5995 Outlet Velocity (FPM) 711 607 643 721 824 748 851 Air Temp. Rise (°F) 53 48 52 47 50 50 51 Max. Mounting Height (Ft.
GENERAL PERFORMANCE DATA - MODELS HDB & BDP Table 9.
BLOWER PERFORMANCE DATA - MODEL HDB Table 10.1 - Power Code Description - HDB Models Power Code 01 Unit Voltage 115/60/1 HDB60 HDB75 HDB100 HDB125 1/4 HP 1/3 HP 1/2 HP 1/2 HP Blower Speed Curves Models (HDB 60-125) Low HDB 60 60 741 55 808 50 889 45 988 40 1111 0.00 0.10 0.20 0.40 0.50 External Static Pressure (IN. WC) 0.60 1270 60 1235 55 1347 50 1481 45 1646 40 1852 35 0.00 0.70 1140 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.
BLOWER PERFORMANCE DATA - MODEL BDP Table 11.
BLOWER PERFORMANCE DATA - MODEL BDP Table 12.1 - Models With or Without Blower Enclosure - Blower Model BDP ➀ ➁ Model Size 150 175 200 250 300 350 400 ATR CFM 0.0” Static Press. RPM HP Drive Turns 0.1” Static Press. RPM HP Drive Turns 0.2” Static Press. RPM HP Drive Turns 0.3” Static Press. RPM HP Drive Turns 0.4” Static Press.
BLOWER PERFORMANCE DATA - MODEL BDP Table 13.1 - Models With or Without Blower Enclosure - Blower Model BDP ➀ ➁ Model Size 150 175 200 250 300 350 400 Data for use with filters only ATR CFM 0.5” Static Press. RPM HP Drive Turns 40 2778 750 45 2469 715 50 2222 685 55 2020 665 60 1852 650 65 1709 640 70 1587 630 40 3241 970 2 45 2881 900 1-1/2 50 2593 845 55 2357 805 60 2160 770 65 1994 745 3.0 830 70 1852 725 1/2 96 0.0 770 3.
GAS CONTROL DATA - ALL MODELS Table 14.
ACCESSORIES Table 15.1 - Field Installed Accessories Feature HD HDB • Downward Air Deflector Hoods - Available in 30°, 60°, and 90° configurations these deflector hoods enable the unit to be mounted higher while still providing heat to the building occupants. Refer to page 16 for further details. Vibration Isolation Kit - Minimizes unit vibration transmission to the building structure.
PERFORMANCE DATA - HOODS FOR PROPELLER MODELS Table 16.
PERFORMANCE DATA - VELOCITY GENERATING NOZZLES Figure 17.1 - Velocity Generating Nozzles 40° DOWNWARD NOZZLE ➀ H T S 90° VERTICAL NOZZLE H S S 5-WAY NOZZLES T 40° SPLITTER NOZZLE T S H S S ➀ Velocity generating nozzles available for Blower Model BDP only. Table 17.1 - Blower Unit Model BDP Velocity Generating Nozzle Performance Data (feet) BDP Blower Model Size Nozzle Type 40° Downward Nozzle 90° Vertical Nozzle 40° Splitter Nozzle 5-Way Nozzle ➁ Max. Mounting Ht. (ft.
UNIT SELECTION Selection Procedure In order to properly select a unit heater it is necessary to have the following basic information. 1. Heating output capacity Model size output is to be matched against the heat loss to be replaced. 2. External static pressure (blower units only) The external static pressure (E.S.P.) is determined using the ASHRAE Guide for duct losses or provided by the design engineer. 3. Accessory internal static pressure (Nozzles, transitions, filters, etc.
UNIT SELECTION Selection Example Conditions (Blower Unit) In the following example, select a unit heater to meet the following conditions: 1. Heating output capacity = 156,000 Btu/Hr per design engineer 2. External Static Pressure = 0.2. 3. Internal Static Pressure = 0.0. No static producing accessories are required 4. Heat exchanger and burner = Aluminized Steel 5. Gas Type = Propane 6. Gas Controls = Two stage Intermittent Pilot 7. Supply Voltage: 230V/60Hz/3Ph 8. Altitude: 1,000 feet 9.
DIMENSIONAL DATA - MODEL HD/HDB Propeller Units - Model HD Blower Units - Model HDB Figure 20.1 - Dimensional Drawings - Model HD Figure 20.2 - Dimensional Drawings - Model HDB 3/8"-163/8"-16 MOUNTING HOLESHOLES 14.9" BETWEEN MOUNTING MOUNTING HOLESHOLES TYP TYP14.9" BETWEEN MOUNTING (MODEL SIZES 100 AND 125 ONLY) (MODEL SIZES 100 AND 125 ONLY) 3/8 x 1"3/8 LONG x 1" LONG G G 3.5" 14.9" BETWEEN 3/8"-163/8"-16 MOUNTING HOLESHOLES 14.
DIMENSIONAL DATA - MODEL PDP Propeller Units - Model PDP Figure 21.1 - Dimensional Drawings C A H M F X W K AA CC DD G J E K B LL BB EE L (MIN. DISTANCE TO WALL) D (OPENING) Table 21.
DIMENSIONAL DATA - MODEL BDP Blower Units - Model BDP Figure 22.1 - Dimensional Drawings C A N F K W X DD CC J S O G AA DD CC 3/4" QxV LOWER FILTER RACK ENCLOS RE (OPTIONAL) (OPTIONAL) L (MIN. DISTANCE TO WALL) M (APPROX.) L (MIN. DISTANCE TO WALL) Table 22.
DIMENSIONAL DATA - MODEL PTP Propeller Units - Model PTP Figure 23.1 - Dimensional Drawings ADJUSTABLE LOUVERS A G 4 MOUNTING HOLES R U T POWER VENTER VENT PIPE CONNECTION S ACCESS PANEL B GAS CONNECTION E OPENING F J D OPENING I C H T-STAT CONNECTION ELECTRICAL CONNECTION MOTOR CORD STRAIN RELIEF M (APPROX) Q (MIN DIST TO WALL) Table 23.1 - Dimensions (inches) - PTP Models PTP150 PTP175 PTP200 PTP250 PTP300 PTP350 PTP400 A 35.53 42.53 42.53 42.53 42.53 42.53 42.
SPECIFICATIONS - ALL MODELS General A. Standards A.1. ETL design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for “Gas Unit Heater and Gas-Fired Duct Furnaces” for safe operation, construction, and performance. B. B.1. B.2. C. C.2. D. D.1. All unit(s) shall include: Mechanical Configuration Furnace(s) section with 80% minimum efficiency provided by an indirect-fired heat exchanger with dimpled tube pattern for efficient heat transfer.
SPECIFICATIONS - ALL MODELS G. G.1. G.2. G.3. G.4. Air Mover J.5. The motor wiring shall be in flexible metal BX conduit. J.7. Propeller models shall meet the following requirements. J.9. The motor horsepower shall be ____. (opt) The motor shall be controlled by a time delay relay (opt) and motor starter. G.4.a. The motor type shall be Single-speed, Totally Enclosed (TE) (Open Drip Proof (ODP) on HD units 75MBH and smaller) G.4.b.
MODEL NOMENCLATURE Figure 26.1 - Model Number Designations PDP 200 A E 01 30 B A N Factory Installed Option Digit N - None Unit Configuration HD - Tubular Power Vented Propeller Unit HDB - Tubular Power Vented Blower Unit PDP - Propeller Unit Power Vent BDP - Blower Unit Power Vent PTP - Tubular Power Vented Propeller Unit Future A - All Dev Digit MBH Input (refer to pages 7 & 9) 100 - 100,000 Btu/hr input 200 - 200,000 Btu/hr input 250 - 250,000 Btu/hr input etc.
THIS PAGE INTENTIONALLY LEFT BLANK 6-189.
The Modine brand has been the industry standard since Arthur B. Modine invented and patented the first lightweight, suspended hydronic unit heater in 1923. No other manufacturer can provide the combined application Products from Modine are designed to provide indoor air-comfort and ventilation solutions for residential, commercial, institutional and industrial applications.