DESIGN BENEFITS
Unit Features - Horizontal Delivery Unit Heaters
Horizontal delivery unit heaters are the most popular of all types.
These units are ideal for heating buildings with large open areas
and low ceilings. They are used to counter heat loss along outside
building walls, especially where windows are present.
In addition to the features noted on page 2, features that
enhance the popularity of the horizontal delivery unit heater are:



This permits the unit to be installed in low clearance areas.



return piping.



HSB MODEL

HC MODEL

Connections – Female type permits direct connection of unit heater to the piping and eliminates the need for additional
fittings.
Vertical Fins
heat transfer.
CoilAll air passes through coil. Heating is uniform. Design assures maximum control over air delivery and temperature
of air leaving the heater. Aluminum fins die-formed for added strength – increased heat transfer. Fins mechanically
bonded to serpentine copper tube.
Motor – All motors are totally enclosed. Single phase and explosion-proof types include built in thermal overload
protection. Selected and tested for operation on specific unit heater models. All motor wiring is terminated in an electrical
junction box either supplied on the unit heater casing, or as an integral part of the motor.
Fan – Lightweight. Blades accurately balanced and pitched to move air quietly and positively – with minimum power
requirement.
Deflector BladesAdjustable horizontal air-deflector blades are standard. Vertical blades are also standard on models

illustrated.
Safety Fan Guard – Standard equipment. Bolted to rear casing, steel rod fan guard completely surrounds the fan
offering constant protection.
Casings
for long life.
Figure 4.1 - Unit Features