User Manual
24
1-150.16
24
PERFORMANCE DATA
Motor Data, Step-Down Transformer Accessory Data
M Ratings shown are for Standard and Low Outlet Temperature Models.
N All HSB/HC units, V/VN 42 thru V/VN, PT/PTN 333 motor HP listed for power code 01. V/VN PT/PTN 333 thru V/VN, PT/PTN 610 motor HP listed for power code
04 and V/PT 952 motor HP listed for power code 05.
O For model sizes V/VN/PT/PTN 385 and above, motors for Power Codes 04, 05, and 10 do not have thermal overload protection.
P For supply voltages of 208V/60Hz/1ph and all non-explosion-proof 3 phase voltages of 208, 230, 460 and 575, Model Numbers indicated with Note P, require that a
115V/60Hz/1 phase Power Code 01 unit heater be used with a shipped loose accessory transformer. See Table 24.2 for Transformer Sizes.
Q For non-explosion-proof 3 phase supply voltages of 208, 230, and 460, Model Numbers indicated with Note Q, can be ordered with a Power Code (208V/3ph=04,
230/460V/3ph=05) that provides a motor matched to the supply voltage with amp draw as shown. Alternately, a 115V/60Hz/1 phase Power Code 01 unit heater could
be used with a shipped loose accessory transformer. See Table 24.2 for Transformer Sizes.
Table 24.1 - Motor Data MN
Figure 24.1
Field Installed Transformer Accessory
Table 24.2 - Step-Down Transformer Accessory Selection
208V/60Hz/1 230/460V/ 575V/60Hz/
or 3 phase 60Hz/3 phase 3 phase
Model Number kVA kVA kVA
HSB/HC 18-63 0.25 0.25
HSB/HC 86-121 0.50 0.50
HSB/HC 165-193 1.00 0.75 0.75
HSB/HC 258-340 1.00 1.00
V/VN 42-59 0.50 0.25 0.25
V/VN 78-139 0.50 0.50
V/VN 161-212 1.00 0.75 0.75
V/VN 247-333 1.00 1.00
PT/PTN 279-333 1.00 1.00 1.00
kVA Size Ship Wt. (Lb.)
0.25 7
0.50 13
0.75 15
1.00 19
0.50
1.00
0.50
1.00
Available Motor Type, Voltage and Power Code
115/60/1 208/60/1 230/60/1 208/60/3 230/460/3 575/60/3 115/60/1 230/460/60/3
Model Number Motor HP O 01 N/A 02 04 05 10 06 09
HSB/HC 18 1/60 3 P 3 P P P 3 -
HSB/HC/HCH 22, 39, 24, 33 1/25 3 P 3 P P P 3 -
HSB/HC 47, 63 1/12 3 P 3 P 3 Q P 3 -
HSB/HC/HCH 67, 104, 86, 108 1/6, 1/8 3 P 3 P 3 Q P 3 -
HSB/HC 121 1/5 3 P 3 3 Q 3 Q P 3 3
HSB/HC/HCH 165, 170, 193, 195 1/3 3
P 3 3 Q 3 Q P 3 3
HSB/HC 258-340 1/2 3 P 3 3 Q 3 Q P 3 3
V/VN 42, 59 1/30 3 P 3 3 Q 3 Q P 3 -
V/VN 78, 95 1/15 3 P 3 3 Q 3 Q P 3 -
V/VN 139 1/5 3 P 3 3 Q 3 Q P 3 3
V/VN 161-212 1/3
3 P 3 3 Q 3 Q P 3 3
V/VN 247 1/2 3 P 3 3 Q 3 Q P 3 3
V/VN, PT/PTN 279 1/2 3 P 3 3 Q 3 Q P 3 3
V/VN, PT/PTN 333 3/4 3 P 3 3 Q 3 Q P - -
V/VN, PT/PTN 385 1 - - - 3 3 3 - 3
V/VN, PT/PTN 500, 610 1-1/2 - - - 3 3 3 - 3
V, PT 952 2 - - - - 3 - -
3
Explosion-proof
Totally Enclosed