Specification

10
9-123.2
PERFORMANCE AND DIMENSIONAL DATA - MODEL OHP
Table 9.1 - Performance and Dimensional Data
Table 9.2 - Clearances to Combustible Materials
Figure 9.1 - Unit Dimensional Drawing
Clearance is 80 in. when heater is fitted with a parabolic reflector.
Model
Housing BTU/Hr input Ship Weight
Recommended Mounting
Heights
Approx. Area
Heated
Control Voltage
OHP 31 430 SS 31,000 59 lbs 8.0' to 12.0' 8' x 8' 24 vac
OHP 34 430 SS 34,000 59 lbs 8.5' to 13.0' 9' x 9' 24 vac
Model Sizes
BTU'Hr Voltage
Mounting
Angle
Side Back Top Below End(s) Front
31,000 (N,P)
31,000 24 vac
18 N/A 13 48 12 N/A
30° N/A 18 18 40 12 36
34,000 (N,P) 34,000 24 vac
18 N/A 13 48 12 N/A
30° N/A 18 18 40 12 36
Heaters mounted on an angle between 1° to 30° must maintain clearances posted for 0° or 30°; whichever is greater.
Figure 9.2 - Clearance to Combustibales