Install Instructions

13
6-580.5
Table 13.1 - Performance - Propeller (PDP) and Blower (BDP) Models
Table 13.4 - Motor Data and Total Unit Power Requirements - Propeller Models
Unit Voltage 115/60/1 115/60/1 With Use of Transformer 208/60/1 230/60/1
Supply Voltage 115/60/1 208V 230V 460V 575V 208/60/1 230/60/1
Mtr. Mtr. Total KVA Total KVA Total KVA Total KVA Total Mtr. Mtr. Total Mtr. Mtr. Total
Amps Rpm Amps Req. Amps Req. Amps Req. Amps Req. Amps Amps Rpm Amps Amps. RPM Amps
1/8 2.3 1625 4.0 0.50 2.4 0.50 2.17 0.50 1.09 0.50 0.87 1.0 1625 1.9 1.0 1625 1.9
1/6 2.7 1075 5.1 1.00 4.81 0.75 3.26 0.75 1.63 0.75 1.30 1.5 1075 2.8 1.5 1075 2.8
1/3 5.4 1075 7.7 1.00 4.81 1.00 4.35 1.00 2.17 1.00 1.74 --- --- --- 2.5 1075 3.7
1/2 7.5 1075 9.8 1.50 7.2 1.50 6.52 1.50 3.26 1.50 2.61 --- --- --- 3.5 1075 4.7
3/4 8.8 1125 11.1 1.50 7.2 1.50 6.52 1.50 3.26 1.50 2.61 --- --- --- 4.4 1125 5.5
All motors are totally enclosed and all single phase motors have built-in thermal overload protection.
Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
(In Canada see rating plate.) Reduction of ratings requires use of a high altitude kit.
Data taken at 55°F air temperature rise. At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods.
A transformer may not be required. 115V/1φ power may be obtained from the following electrical distribution systems: 230/1φ 3-wire, 230/3φ
4-wire, 208/3φ 4-wire and 208/1φ 3-wire (from 208V wye connected transformer). Please consult the job site electrician to determine applicability.
Unit power code must match building supply voltage, control voltage must match unit power.
For CSA Canada certification, step down transformer may be required to be factory installed (Blower Models Only).
Table 13.5 - Motor Data and Total Unit Power Requirements - Blower Models
HP
Voltage 115/60/1 230/60/1 208/60/3 230/60/3 460/60/3 575/60/3
Motor Motor Total Motor Total Motor Total Motor Total Motor Total Motor Total
HP Rpm Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps
1/4 1725 3.7 6.0 2.7 4.0 1.3 2.6 1.2 2.5 0.7 1.9 0.5 1.8
1/3 1725 5.0 7.3 2.5 3.8 1.2 2.5 1.2 2.5 0.6 1.9 0.8 2.1
1/2 1725 8.0 10.3 4.0 5.3 2.2 3.5 2.1 3.4 1.1 2.4 0.9 2.2
3/4 1725 11.0 13.3 5.4 6.7 2.8 4.1 2.7 4.0 1.4 2.6 1.1 2.3
1 1725 13.4 15.7 6.7 8.0 3.6 4.9 3.5 4.8 1.8 3.0 1.5 2.6
1-1/2 1725 15.2 17.5 7.6 8.9 4.8 6.1 4.8 6.1 2.4 3.6 1.9 3.1
2 1725 --- --- --- --- 6.8 8.1 6.0 7.3 3.0 4.3 2.3 3.5
3 1725 --- --- --- --- 9.9 11.2 8.2 9.5 4.1 5.4 3.4 4.6
5 1725 --- --- --- --- 15.2 16.5 13.0 14.3 6.5 7.8 5.3 6.5
GENERAL PERFORMANCE DATA
Model Number
PDP 150 PDP 175 PDP 200 PDP 250 PDP 300 PDP 350 PDP 400 BDP 150 BDP 175 BDP 200 BDP 250 BDP 300 BDP 350 BDP 400
Btu/Hr. Input 150,000 175,000 200,000 250,000 300,000 350,000 400,000 150,000 175,000 200,000 250,000 300,000 350,000 400,000
Btu/Hr. Output 120,000 140,000 160,000 200,000 240,000 280,000 320,000 120,000 140,000 160,000 200,000 240,000 280,000 320,000
Entering Airflow (CFM)
2180 2550 2870 3700 4460 4870 5440 2020 2357 2694 3367 4040 4714 5387
CFM Range 1587-2778 1852-3241 2116-3704 2646-4630 3175-5556 3704-6481 4233-6584
Air Temp. Rise (°F) 51 51 52 50 50 53 54 40-70 40-70 40-70 40-70 40-70 40-70 40-70
Max. Mounting Hgt.
(Ft) 16 17 15 19 21 20 19 14 15 13 16 18 19 19
Heat Throw (Ft)
(Max. Mtg. Hgt.) 55 59 51 67 74 70 69 49 52 47 58 64 67 68
Motor Type PSC PSC PSC PSC PSC PSC PSC
15/60/1 (PC01) 1/8 1/6 1/6 1/3 1/2 3/4 3/4
30/60/1 (PC02) 1/8 1/6 1/6 1/3 1/2 3/4 3/4
208/60/1 (PC03
)
N/A 1/6 1/6 N/A N/A N/A N/A
HP
For motor size details, refer to pages 14 and 15.
Table 13.2 - Electrical Details Propeller Units Table 13.3 - Electrical Details Blower Units
Power
Power
Supply
Voltage
Supply
Voltage
Control
Code
Selected
Control
Code
Selected
Factory
Installed
Transformer
Factory
Installed
Transformer
Additional
Field Installed
Transformers
Additional
Field Installed
Transformers
Unit
Voltage
Voltage Phase Voltage Phase
115 1 115 1 30,63,85,87 115 to 24 none
208 1 115 1 30,63,85,87 115 to 24 208V to 115V
208 1 208 1 31,64,86,88 208 to 24 none
208 3 115 1 30,63,85,87 115 to 24 208V to 115V
230 1 115 1 30,63,85,87 115 to 24 208 to 115V
230 1 230 1 31,64,86,88 230 to 24 none
230 3 115 1 30,63,85,87 115 to 24 230V to 115V
460 3 115 1 30,63,85,87 115 to 24 460 to 115V
575 3 115 1 30,63,85,87 115 to 24 575 to 115V
Unit
Voltage
Voltage Phase Voltage Phase
115 1 115 1 30,63,85,87 115 to 24 none
208 1 208 1 31,64,86,88 208 to 24 none
208 3 208 3 31,64,86,88 208 to 24 none
230 1 230 1 31,64,86,88 230 to 24 none
230 3 230 3 31,64,86,88 230 to 24 none
460 3 230 3 64,88 230 to 24 460 to 230V
460 3 460 3 32,93 460 to 24 460 to 230V
575 3 230 3 64,88 230 to 24 575 to 230V
575 3 575 3 33,94 575 to 24 575 to 230V