AccuSpec V4.31b Transaction #: JOB TITLE: Date: 12/18/2020 Approved By: Submittal review and approval required prior to listed unit(s) being released for production and shipment. Unit(s) configured based on information provided. The Approver is responsible for ensuring the units, options, and accessories meet the job specifications.
AccuSpec V4.31b SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Location: Submitted by: Amy Voltz Date: 12/18/2020 Engineer: Architect: Contractor: Unit Tag Model Number Quantity of Units Btu/Hr Input Btu/Hr Output CFM Altitude Temperature Rise (degrees F) External Static Pressure (E.S.P) Total Static Pressure (T.S.P.
AccuSpec V4.
AccuSpec V4.
AccuSpec V4.31b GENERAL PERFORMANCE DATA General Performance Data Model At 0’ Elevation Btu/Hr. Input Btu/Hr. Output Entering Airflow (CFM) Outlet Velocity Air Temp. Rise (°F) Mounting Height (Max Ft.)1 Heat Throw (Max. Mtg. Ft.)2 Unit Total Power (Amps) PDP350 350,000 290,500 4870 1068 55 20 70 11.15 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 350,000 Btu/Hr.
AccuSpec V4.31b DIMENSIONS – UNIT Model PDP Dimensions Model Size Dimensions (inches) A 33.625 B 40.25 C 25 D 31.1875 E 24 F N/A G 7.5 H 30 J (Round) 1 6 K (Mtg Holes) 2 3/8-16 L3 40.75 M 34.6875 1 2 3 4 PDP350 W X AA BB CC DD EE LL 5 16 9 7.25 N/A 3.375 32.875 35.5 Gas Connection4 Fan Diameter Approx. Shipping Weight 3/4 22 355 lbs. For some models, this is the dimension of the vent transition outlet supplied with unit. PDP150 through PDP 300 have 2 holes and the level hanging adjustment feature.
Standards All unit(s) shall include: The gas fired unit heater(s) shall include ETL design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for “Gas Unit Heater and Gas-Fired Duct Furnaces” for safe operation, construction, and performance. Mechanical Configuration Furnace(s) section with 82% minimum efficiency provided by an indirect-fired heat exchanger with dimpled tube pattern for efficient heat transfer.
The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100% full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat.