6-170.9
GENERAL PERFORMANCE AND ELECTRICAL DATA - MODEL PTC
Table 5.1 - Propeller Unit Heater Model PTC General Performance Data
Table 5.2 - Model PTC Operating Electrical Data
Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above
sea level (in Canada see rating plate). Reduction of ratings requires use of a high altitude kit.
Data taken at 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods.
All motors used are produced, rated and tested by reputable manufacturers in accordance with NEMA standards and carry the standard warranty of both
the motor manufacturer and Modine. All motors are totally enclosed and all single phase motors have built-in thermal overload protection.
Amp draw data shown is operating amp draw at incoming power. For units that use a field installed accessory step-down transformer as noted, the amp draw shown is
the primary side operating amp draw. For sizing of circuit protection for equipment with transformers, please refer to the National Electric Code.
Model PTC Sizes
55 65 85 110 135 156 180 215 260 310
Btu/Hr Input
55,000 65,000
85,000 110,000 135,000 155,000 180,000 215,000 260,000 310,000
Btu/Hr Output
51,150 60,450
79,050 102,300 125,500 144,150 167,400 199,950 241,800 288,300
Condensate Production (Gal./Hr.)
0.3 0.4
0.5 0.7 1.0 1.1 1.3 1.6 1.9 2.3
Entering Airflow (CFM) @ 70°F
1097 1141
1650 1750 2160 2600 3020 3865 4585 5400
Outlet Velocity (FPM)
618 650
619 668 719 862 676 699 831 765
Air Temp. Rise (°F)
43 49
44 54 54 51 51 48 49 49
Max. Mounting Height (Ft.)
12 12
13 13 14 18 15 17 20 19
Heat Throw (Ft.) @ Max. Mtg Ht
43 43
48 46 51 62 53 60 70 67
Motor Type
PSC PSC
PSC PSC PSC PSC PSC PSC PSC PSC
Motor HP
1/8 1/8
1/8 1/3 1/3 1/3 1/3 1/2 3/4 3/4
Motor RPM
1440 1440
1550 1075 1075 1075 1075 1075 1125 1125
Supply
Voltage
Power Code
Model PTC Sizes
55 65 85 110 135 156 180 215 260 310
115V
1 Phase
01 (115V)
Motor Amps 2.20 2.20 2.20 4.60 4.60 4.60 4.60 7.00 8.80 8.80
Total Amps 4.35 4.35 4.35 6.75 6.75 6.75 6.75 9.15 10.95 9.85
Transformer kVA n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
208V
1 or 3 Phase
01 (115V) with
Transformer
Transformer kVA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.50 1.50 1.50
208V Total Amps 2.41 2.41 2.41 3.73 3.73 3.73 3.73 5.06 6.05 5.45
230V
1 or 3 Phase
01 (115V) with
Transformer
Transformer kVA 0.75 0.75 0.75 1.00 1.00 1.00 1.00 1.50 1.50 1.50
230V Total Amps 2.18 2.18 2.18 3.38 3.38 3.38 3.38 4.58 5.48 4.93
460V
3 Phase
01 (115V) with
Transformer
Transformer kVA 0.75 0.75 0.75 1.00 1.00 1.00 1.00 1.50 1.50 1.50
460V Total Amps 1.09 1.09 1.09 1.69 1.69 1.69 1.69 2.29 2.74 2.46
575V
3 Phase
01 (115V) with
Transformer
Transformer kVA 0.75 0.75 0.75 1.00 1.00 1.00 1.00 1.50 1.50 1.50
575V Total Amps 0.87 0.87 0.87 1.35 1.35 1.35 1.35 1.83 2.19 1.97