Submittal Data Sheet

AccuSpec V4.24ha
GENERAL PERFORMANCE DATA
General Performance Data
Model PTC 180
At 0’ Elevation
Btu/Hr. Input 180,000
Btu/Hr. Output 167,400
Entering Airflow (CFM) 3020
Outlet Velocity 676
Air Temp. Rise (°F) 51
Mounting Height (Max Ft.)
1
15
Heat Throw (Max. Mtg. Ft.)
2
53
Unit Total Power (Amps) 6.75
Condensate Produced (gal/hr) 1.3
As Configured at 0-2000 Ft. Elevation
Btu/Hr. Input 180,000
Btu/Hr. Output 167,400
Configured Air Temp Rise (°F) 51
Motor Data
Horse Power 1/3
RPM 1075
Type P.S.C.
Motor Amps at 115V 4.60
Clearances to Combustibles
Top and Bottom 6”
Vent/Combustion Air Connector 6”
Access Side 6”
Non-Access Side 6”
Rear 18”
1
At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit.
2
Heat Throws are calculated at 65°F ambient with a 51°F air temperature rise with the unit mounted at a maximum mounting
height of 15 feet.