PERFORMANCE DATA - ALL MODELS
➀ Airflow shown is at 70°F
ambient and heating at
full rated capacity.
➁ For HER, airflow CFM is
for inlet. For PTE and
VE, airflow CFM is outlet.
➂ For HEX units above
6000 feet above sea
level, altitude limits may
exist. Refer to the latest
revision of Installation &
Service Manual 2-519.
Location & Air
Delivery Type
Model
Heating Capacity
Air Data
High Stage Low Stage
kW Btu/hr kW Btu/hr
Airow
(CFM)
Temp Rise
(°F)
Heat Throw
(ft.)
Maximum Mounting
Height (ft.)
Standard Locations
Horizontal Delivery
HER 30 3 10,200 n/a n/a 380 25 12 8
HER 50 5 17,100 n/a n/a 380 42 12
8
HER 75 7.5 25,600 n/a n/a 530 45 14 8
HER100 10 34,100 n/a n/a 830 38 20 9
HER125 12.5 42,700 n/a n/a 830 48 20 10
HER150 15 51,200 n/a n/a 830 57 20 10
HER200 20 68,200 n/a n/a 1300 49 25 11
HER250 25 85,300 n/a n/a 1300 61 25 12
PTE300 30 102,400 15 51,200 2575 40 75 17
PTE400 40 136,500 20 68,200 2575 54 60 15
PTE500 50 170,600 25 85,300 2575 70 45 14
Vertical Delivery
VE 50 5 17,100 n/a n/a 800 21
See Table 7.1 for Throw/Mounting
Height Data.
VE 75 7.5 25,600 n/a n/a 800 31
VE 100 10 34,100 n/a n/a 940 36
VE 150 15 51,200 n/a n/a 1340 38
VE 200 19 64,800 n/a n/a 1600 41
VE 250 25 85,300 n/a n/a 1600 55
VE 300 30 102,400 15 51,200 2575 40
VE 400 40 136,500 20 68,200 2575 54
VE 500 50 170,600 25 85,300 2575 70
Hazardous Locations
(Explosion Proof)
Horizontal Delivery
HEX___-3 3 10,250 n/a n/a 500 19 15 7
HEX___-5 5 17,050 n/a n/a 500 31.6 15 7
HEX___-7.5 7.5 25,600 n/a n/a 850 27.9 30 10
HEX___-10 10 34,100 n/a n/a 850 37.2 30 10
HEX___-15 15 51,200 n/a n/a 1750 27.1 40 10
HEX___-20 20 68,250 n/a n/a 1750 36.1 40 10
HEX___-25 25 85,300 n/a n/a 3600 21.9 70 20
HEX___-30 30 102,350 n/a n/a 3600 26.3 70 20
HEX___-35 35 119,450 n/a n/a 3950 28 70 20
Model
Power Code, Supply Voltage (60Hz) Motor Information
11 12 31 32 33
Motor HP Motor Type
Motor
Bearing Type208V/1ph 240V/1ph 208V/3ph 240V/3ph 480V/3ph
HER 30 14.9 12.9 8.8 7.7 3.8
1/40
Totally Enclosed,
Shaded Pole
Sleeve
HER 50 24.5 21.3 14.3 12.5 6.2
HER 75 36.5 31.7 21.3 18.5 9.2
HER 100 49.4 42.9 29.0 25.3 12.7
1/15
HER 125 - - 36.0 31.4 15.7
HER 150 - - 42.9 37.4 18.7
HER 200 - - 56.8 49.4 24.7
HER 250 - - 70.7 61.4 30.7
PTE300 - - - -
37.6 / 19.5 ➃
1/6
Totally Enclosed,
Permanent Split
Capacitor
Ball
PTE400 - - - -
49.6 / 25.5 ➃
PTE500 - - - -
61.5 / 31.5 ➃
VE 50 - 21.4 14.5 12.7 6.7
1/15
Totally Enclosed,
Shaded Pole
Sleeve
VE 75 - 31.9 21.4 18.6 9.7
VE 100 - 42.3 28.3 24.6 12.7
VE 150 - - 42.5 37.0 19.0
1/8
Totally Enclosed,
Permanent Split
Capacitor
Ball
VE 200 - - - 49.0 25.0
VE 250 - - - - 31.0
VE 300 - - - -
37.6 / 19.5 ➃
1/6
VE 400 - - - -
49.6 / 25.5 ➃
VE 500 - - - -
61.5 / 31.5 ➃
HEX5- ➄ 60-3.0
14.4 12.5 8.3 7.2 3.6
1/2 Explosion Proof Ball
HEX5- ➄ 60-5.0
24.0 20.8 13.9 12.0 6.0
HEX5- ➄ 60-7.5
36.1 31.3 20.8 18.0 9.0
HEX5- ➄ 60-10.0
- 41.7 27.8 24.1 12.0
HEX5- ➄ 60-15.0
- - - 36.1 18.0
HEX5- ➄ 60-20.0
- - - - 24.1
HEX5- ➄ 60-25.0
- - - - 30.1
HEX5- ➄ 60-30.0
- - - - 36.1
HEX5- ➄ 60-35.0
- - - - 42.1
Table 6.2 - Unit Electrical Amp Draw and Motor Data - All Models
➃
When two amp draws are shown, the first is at high stage heat, the second is at low stage heat.
➄
The four missing digits indicate voltage and phase. Example: A 480V/3ph HEX model with 30kW rating would have a full model number of HEX5-480360-30.0.
Refer to Table 10.1 for a complete listing of full model numbers available.