Instructions

F
User Manual MODSTER Charger 60
www.modster.at 47
This program is only suitable for charging Pb lead-acid battery with
nominal voltage from 6 to 12V, Pb lead-acid battery is a completely
different from NiMH/NiCD battery. These batteries can only deliver
current lower in comparison to their capacity. The same restriction
applies to the charging process consquently, the optimum charge
current can only be 1/10 of the capacity. Pb battery can not be used
for fast-charging. Please follow the instructions provided by the
battery manufacturer.
CHARGING OF PB BATTERY
Set up the charge current on the left and
nominal voltage on the right. Range of
current 0.1-6.0A, the voltage should match
the battery being charged. Press START/
ENTER button for more than 3 seconds to
start charging.
The screen display the real-time charging
status. Press START/ENTER button again
to store the parameter value you set. Press
BATT TYPE/STOP button to end the
program.
Start
Enter
Batt type
Stop
>3 seconds
DEC. INC. DEC. INC.
Batter y
typ e
-
Elapse d
time
+
Charge
curren t
Batter y
voltag e
-
+
Charge d
capacit y
Pb-6 4.0A 14.40V
CHG 022:43 001300
DISCHARGING OF PB BATTERY
Set up the discharge current on the left and
nominal voltage on the right. Range of
discharge current is 0.1-2.0A, the voltage
should match the battery being discharged.
Press ENTER/START button for more than
3 seconds to start discharging.
Start
Enter
Batt type
Stop
>3 seconds
DEC. INC
.
DEC. INC.
-
+
-
+