MODEL: MSPG Series OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc. 2166 Zeus Court Bakersfield, CA 93308 Tel.: (661) 392-7600 FAX.: (661) 392-7601 E-Mail: sales@modypump.com http://www.modypump.
LIFE IS PRECIOUS - THINK SAFETY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. Most accidents can be avoided by using COMMON SENSE. Please read the operation and maintenance instruction manual supplied with the pump. If you did not receive one, please call your local distributor before pump installation. Do not wear loose apparel that may become entangled in the impeller or other moving parts.
Contents Identification plate General description Applications Product description Handling Installation Electrical connections Operation Service & maintenance Technical data Motor winding connection schemes be used for fitting, operation and maintenance of standard submersible waste water pumps. 1 1 1 1 1 2 3 3 3 Identification plate Cooling system Applications This starting & operation manual are applicable to the electric driven submersible waste water pumps specified on the front page.
After a long period of storage, the pump must be inspected carefully. Rotate the impeller by hand before start-up and check carefully seals and cable entry adjustment, the legs are set and fixed by two screws that lock the pump arrangement into position. The bottom leg pads can then be secure by bolting and anchoring them in the concrete foundation. WARNING! Never start up the pump without impeller.
Operation Before initial start-up after repair or in a new installation, always check direction of rotation. The pump must always rotate in an anti-clockwise direction. If the rotation is clock-wise, transpose two phases in the electric control panel so that it will change to proper rotational direction. Be aware of the starting torque, it may be very strong depending on the size of the pump. Do not hold the pump when checking the rotation.
3 ~ Direct on –line starting DOL Motor connection: Ʀ 1 Power Supply Cable + 1 Control Cable Color Coding Power Supply U V W PE Black Brawn Grey Yellow 3~ Direct - on - line starting DOL Motor connection : ǻ PE F1 F2 D* Control Black Brawn Grey U F1 F2 D V W U V W PE F1 F2 D* Black-1 Black-2 Black-3 Yellow Black-4 Black-5 Black-6 *Not available for PX1-65.
3 ~ Star-Delta starting Y- Ʀ Motor connection: ǿǿǿ Ʀ Power Supply (cable1) U1 V1 W1 PE Black Brawn Grey Yellow Power Supply (cable2) U2 V2 W2 PE Black Brawn Grey Yellow Control F1 F2 D Black Brawn Grey 1 Power Supply Cable + 1 Control Cable Color Coding Power Supply Control U1 V1 W1 PE U2 V2 W2 PE Black-1 Black-2 Black-3 Yellow Black-4 Black-5 Black-6 Yellow F1 F2 D Black Brawn Grey F1 F2 D U2 V2 W2 U1 V1 W1 1 Power Supply and Control Cable Color Coding U1 V1 W1 U2 V2 W2 PE F1 F2 D Black
A C B D E F 56 53 8 8 25 39 26 45 14 44 7 55 6 21 31 7 7 18 33 46 40 13 16 1 54 33 6 6 29 34 32 2 28 17 51 19 5 5 30 12 24 43 24 50 37 23 15 48 4 4 47 27 3 42 10 35 11 3 3 4 36 22 49 8 5 38 46 52 20 2 2 9 41 SIGNATURE NAME DESIGN MODY PUMPS, INC DEBUR AND BREAK SHARP EDGES FINISH: DATE MSPG2 TITLE: STELIOS GRINDER PUMP ASSEMBLY 1 CHK'D APPV'D MFG MATERIAL: Q.A DWG NO.
PARTS LIST MODY MSPG2 GRINDER ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14a 15 15a 16 17 18 19 20 21 22 23 24 25 25a 26 27 28 29 30 31 32 33 33 34 35 36 37 39 40 41 42 3/4/2008 DESCRIPTION LATCH BOLT (FAST LOCK) (SMALL) LOWER BEARING HOUSING WASHER SPACER IMPELLER CG2 WEAR PLATE BEARING LOWER ΚΕΥ GRINDER DISC (stationary) GRINDER ( rotary) GASKET VOLUTE LOWER COOLING FLANGE UPPER BEARING HOUSING SHAFT ROTOR PX2-1 SHAFT ROTOR PX2-2 STATOR HOUSING MSP2-1 STATOR HOUSING MSP2-2 MOISTURE SENSOR COOLING JACKET MOT
PARTS LIST MODY MSPG2 GRINDER ITEM 43 44 45 46 46 47 48 49 50 51 52 53 54 55 56 3/4/2008 DESCRIPTION SCREW SCREW SCREW SCREW SCREW BOLT O-RING O-RING O-RING O-RING O-RING CABLE QTY 4 4 4 6 9 4 4 3 2 1 1 1 1 1 MATERIAL stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 NBR NBR stainless steel 304 NBR NBR NBR Page 2 of 2
RETURNED GOODS POLICY: RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION” OR RGN NUMBER. CONTACT YOUR LOCAL MODY PUMPS INC. DISTRIBUTOR OR THE FACTORY DIRECTLY. PRODUCTS THAT ARE RETURNED MUST BE PRESSURE WASHED, CLEANED, SANITIZED AND DECONTAMINATED AS NECESSARY PRIOR TO SHIPMENT. THIS ENSURES THAT EVERYONE IN CONTACT WITH RETURNED UNITS ARE NOT EXPOSED TO HEALTH HAZARDS. ALL APPLICABLE LAWS AND REGULATIONS SHALL APPLY.
LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in material and workmanship under normal use and service for the following time periods, when installed and maintained in accordance with our instructions. PUMPS: One (1) year from date of installation or (18) months from date of shipment, whichever occurs first.