Range Hoods www.moffatappliances.ca Safety Information . . . . . . . . . . . 2 Operating/Care and Cleaning Instructions Charcoal Filter . . . . . . . . . . . . . . .4 Grease Filter . . . . . . . . . . . . . . . . .3 Hood Light . . . . . . . . . . . . . . . . . .4 Hood Surfaces . . . . . . . . . . . . . . . .4 Controls . . . . . . . . . . . . . . . . . . . . .3 Owner’s Manual and Installation Instructions TV337*–Vent options only Installation Instructions . . .5–13 Consumer Support Consumer Support . . .
Safety Instructions IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS WARNING – TO REDUCE THE RISK OF FIRE, Operating Instructions ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
Safety Instructions Using the hood controls. Throughout this manual, features and appearance may vary from your model. Switch Pad Controls (on some models) Control Knobs (on some models) ON OFF LO MED HI HI OFF ON NITE OFF OFF LO LIGHT Control Turn to HI, MED or LO as needed. Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning.
Safety Instructions Charcoal Filter—Recirculating Installations Only Replaceable charcoal filter Operating Instructions NOTE: DO NOT rinse, or put charcoal filters in an automatic dishwasher. The charcoal filter cannot be cleaned. It must be replaced. Order filter no. WB02X10700. Replacement filters can be ordered from your GE supplier. If the hood is not vented to the outside, the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors.
Range Hood Installation Instructions Questions? Call 1-800-561-3344 or Visit our Website at: www.moffatappliances.ca BEFORE YOU BEGIN DUCTWORK REQUIREMENTS** Read these instructions completely and carefully. NOTE: Read the ductwork sections only if you do not have existing ductwork. If you have existing ductwork, skip to the “Damage” section and proceed. • IMPORTANT – Save these instructions for local inspector’s use. • • • • • • • The venting system must exhaust to the outside.
Installation Instructions WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH* DUCT PIECES EQUIVALENT NUMBER LENGTH x USED = TOTAL 3¼” x 10” Rect., straight 1 Ft. x ( 7” Round, straight 1 Ft. 6” Round, straight 1 Ft. 3¼” x 10” Rect. 90° elbow 14 Ft. x ( ) = Ft. 3¼” x 10” Rect. 45° elbow 8 Ft. x ( ) = Ft. 3¼” x 10” Rect. 90° flat elbow 33 Ft. x ( ) = Ft. 3¼” x 10” Rect. wall cap with damper 24 Ft. (18 ft. w/o damper) x ( ) = Ft. x ( ) = Ft. 3¼” x 10” Rect.
Installation Instructions DAMAGE – SHIPMENT/INSTALLATION TOOLS YOU WILL NEED • If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement. • If the unit is damaged by the customer, repair or replacement is the responsibility of the customer. • If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.
Installation Instructions 1 CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from the below choices. A IMPORTANT: If the hood is to be installed in a recirculating, non-vented ductless manner, do not knock out any vent openings in the hood. Only an electrical access hole will be knocked out of the hood. Outside top exhaust (Vertical duct–3¼” x 10” Rectangular)* C TV337 TV337 * 1” = 2.5 cm * 1” = 2.
Installation Instructions 2 REMOVE EXHAUST ADAPTOR* 5 REMOVE WIRING KNOCKOUT If exhausting/venting using the 3¼” x 10” rectangular duct Remove the exhaust adaptor from the inside of the hood. Set it aside along with its mounting screws. Remove either the top or the back wiring knockout as needed and install an approved strain relief clamp.
Installation Instructions 9 MARK HOLES* 7 FOR 7” ROUND VERTICAL Select the vent option that your installation will require and proceed to that section: DUCTED DISCHARGE INSTALLATIONS ONLY:* A.Outside top exhaust (Vertical duct–3¼” x 10” Rectangular) Bend up the duct alignment ears in preparation for later attachment of the 7” duct. • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.
Installation Instructions C.Outside rear exhaust (Horizontal duct–3¼” x 10” Rectangular) 12 SCREW IN PARTWAY Drive a mounting screw (from the hardware packet) partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom. • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.
Installation Instructions 17 INSTALL LIGHT BULB 15 SECURE HOOD NOTE: A light bulb is not shipped with the hood. Obtain one locally. Purchase and install an ordinary screw-base light bulb, not more than 60 watts. Slide the hood back against the wall. Tighten the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot. Mounting screw (4) Keyhole (4) 18 FOLLOW ELECTRICAL CODE Complete the electrical wiring according to National Electrical Code and local codes.
Installation Instructions 20 REPLACE WIRING COVER TROUBLESHOOTING CHECKLIST If the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems inadequate, check the following: ❏ Knockouts not removed from hood. ❏ Damper blade not opening. ❏ Reduced airflow because the duct is too small or the duct length is too long. ❏ The duct is blocked. ❏ Undersized or restrictive wall or roof cap.
Safety Instructions Operating Instructions All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at GEAppliances.ca, or call 1-800-561-3344. Please have serial number and model number available when calling for service. Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty.
Consumer Support. Moffat Appliances Website www.moffatappliances.ca Have a question or need assistance with your appliance? Try the Moffat Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line. Schedule Service www.moffatappliances.ca Expert Mabe repair service is only one step away from your door.