Specifications

Maintenance
TX,FF,121 –19–15MAR93–1/1
USING BATTERY CHARGER
TS204 –UN–23AUG88
Ö
CAUTION: Prevent possible injury from
exploding battery. Do not charge a battery if
the battery is frozen or it may explode. Warm
battery to 16°C (60°F). Disconnect battery
ground (—) clamp before you charge batteries
in the machine to prevent damage to electrical
components.
IMPORTANT: Do not use a battery charger as a
booster if a battery has a 1.150 specific
gravity reading or lower. Turn off
charger before connecting or
disconnecting it.
A battery charger may be used as a booster to start
engine.
TX,90,JC1146 –19–23MAY96–1/1
REPLACING BATTERIES
Your machine is equipped with a negative ground
electrical system. It uses one or two 12-volt batteries. If
one of the two batteries fails, both batteries must be
replaced. Use only batteries meeting following
specifications.
BCI Group Size: 27
544G, 624G:
625 cold cranking amps at -18°C(0°F)
160 minutes reserve capacity at 25 amps
644G:
950 cold cranking amps at -18°C(0°F)
180 minutes reserve capacity at 25 amps
90–14