Operational Checkout
–1/1
)MONITOR INDICATOR AND GAUGE CHECKS (ENGINE RUNNING)
–1/1
MONITOR DISPLAY AND
ALTERNATOR OUTPUT
CHECK
T7825BD –UN–21AUG92
Turn key switch to on and wait 5 seconds.
LOOK: Hourmeter reading must appear.
T7825BC –UN–21AUG92
Press SELECT button once.
LOOK: Battery volts reading must be 12.3—13.8.
T7825BF1 –UN–24AUG92
Press SELECT button once.
LOOK: Engine rpm must read 0.
Press SELECT button once.
LOOK: MPH reading must be 0.
Press SELECT button once.
LOOK: km/H reading must be 0.
T8368BP –UN–02JAN94
Start engine and run at slow idle. Observe monitor
display.
LOOK: The following engine rpm readings must be
displayed. 544G/624G: 825—875 rpm 644G: 775—825
rpm (SN -544523) 875—925 rpm (SN 544524- )
95–7
PN=215