Datasheet
SNAKE CABLES
24
STANDARD VERSION
Part No.
No. Of
Channels
Ov. Dia.
(Approx. mm)
Jacket Thickness
(Approx. mm)
Weight
(kg/100m)(kg/328Ft)
Maximum
Length available
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2- ch
4- ch
8- ch
12- ch
16- ch
19- ch
24- ch
27- ch
32- ch
48- ch
7.5(0.295")
8.6(0.339")
11.5(0.453")
14.3(0.563")
15.8(0.622")
17.0(0.669")
20.0(0.787")
20.5(0.807")
21.7(0.854")
26.0(1.02")
1.0(0.039")
1.0(0.039")
1.2(0.047")
1.5(0.059")
1.5(0.059")
1.7(0.067")
2.0(0.079")
2.0(0.079")
2.0(0.079")
2.0(0.079")
7
9
18
28
32
40
46
58
63
97
506m
(1.659Ft)
305m
(1.000Ft)
200m (656Ft)
( Figures in parenthesis are in inches )
CABLE CORE SPECS
Conductor
Insulation
Drain Wire
Shield
Jacket(Covering)
Identification
30/0.08A (0.15mm
2
) #26AWG
1.0φ XLPE (Cross Linked Polyethylene )
7/0.18TA (0.18mm
2
) #25AWG
Approx. 60/0.10A Served (spiral ) Shield
2.8φ Flexible PVC
See core number identification table
(30×#40AWG)
(0.039"
φ)
(7×#33AWG)
(0.110"
φ)
ELECTRICAL & MECHANICAL CHARACTERISTICS
DC Resistance at 20℃
Capacitance at 1 kHz, 20℃(Partial Capacitance Value )
See Figure (1)
Inductance
Electrostatic Noise (Hum Pick-up )
Electromagnetic Noise at 10kHz
( Inductance of the toroidal core: 595μH)
Microphonics
Method: Stepping on cable
Voltage Breakdown
Insulation Resistance at DC 125V, 20℃
Tensile Strength of one pair ( 26℃,65% RH )
Emigration
Applicable Temperature
Standard
Inner Pair Conductor
Shield
Ko
K1
0.13Ω/m ( 0.040Ω/Ft )
0.030Ω/m ( 0.0092Ω/Ft )
130pF/m ( 40pF/Ft )
12pF/m ( 3.7pF/Ft )
0.6μH/m ( 0.18μH/Ft )
2.5mV Max.
0.1mV Max.
50mV at 50kΩ Load
Using standard testing methods of Mogami Wire & Cable Corp.
Figure(1)
K0 K0K1
Standard EZID models with 19 channels or more are designed for studio applications only. For PA and/or
non-statistical applications, use the CL2 rated version.
REMARKS:
*
*
*
*
Must withstand at DC 500V/15sec.
10
5
MΩ・m Minimum
274 N
Non-Emigrant to ABS resin
-20˚C~+70˚C (-4˚F~+158˚F)
UL13 CL2X 60˚C