Installation
© 2017 Mohawk Group | mohawkgroup.com
Page 4 / 8
Glue Down Commercial Resilient Tile | INSTALLATION
• APA rated Sturdi-I-Floor panels are designed as combination suboor/underlayment, but exposure to construction conditions
including weather may necessitate installation of a 1/4” underlayment panel prior to resilient ooring installation.
• Mohawk Group resilient ooring is not recommended directly over re-retardant treated plywood or preservative treated
plywood. The materials used to treat the plywood may cause problems with adhesive bonding. An additional layer of APA
rated 1/4” thick underlayment should be installed.
Strip – Plank Wood Flooring
Due to expansion and contraction of individual boards during seasonal changes, Mohawk recommends 1/4” or thicker APA rated
underlayment panels be installed over suboors if product will be glued down.
Resilient Floor Covering
• Must be single layered, non-cushion backed, fully adhered, and smooth.
• Show no signs of moisture or alkalinity.
• Wax, polish, grease and grime must be removed.
• Cuts, cracks, gouges, dents and other irregularities in the existing oor covering must be repaired or replaced.
Note: The responsibility of determining if the existing ooring is suitable to be installed over rests solely with installer/ooring
contractor on site. If there is any doubt as to suitability, the existing ooring should be removed or an acceptable underlayment
installed over it. Installations over existing resilient ooring may be more susceptible to indentation.
Poured Floors (Epoxy, Polymeric, Seamless)
• Must be totally cured and well bonded to the concrete.
• Must be free of any residual solvents and petroleum residue.
• Wax, polish, grease and grime must be removed.
• Cuts, cracks, gouges, dents and other irregularities in the existing oor covering must be repaired or replaced.
• Texture must be smooth.
• Show no signs of moisture or alkalinity.
Old Adhesive Residue
• If the adhesive residue is asphalt-based (cut-back) or any other type of adhesive is present, it must be dealt with in one
of two ways:
• It may be mechanically removed using methods such as bead blasting or scarifying, or
• A Portland-based self–leveling underlayment may be applied over it. Check with the underlayment manufacturer for
suitability, application instructions, and warranties.