SITE CONDITIONS
Concrete slabs must be tested for moisture by the current version of ASTM F2170. (Consult CRI 104 part 6.2 for standard test
method for determining relative humidity on concrete floor slabs using In-Situ Probes.) Below are the requirements for each
Mohawk Group Carpet Tile products.
Ecoflex NXT & Ecoflex MATRIX
The following applies to new pour concrete and renovation:
On or Below Grade:
An ASTM E-1745, Class B minimum vapor barrier must be in place and directly in contact with the concrete
If reading is below 95% RH, Mohawk Group approved adhesive or FlexLok tabs only
If reading exceeds 95% RH, and no signs of visible moisture are present, Mohawk FlexLok tabs are an approved
installation method. This does not mitigate any existing moisture issues and complete removal of existing flooring
and reducing old adhesive to a smooth surface.
Above Grade:
If reading is below 95% RH, use Mohawk approved adhesive or FlexLok tabs only
If reading exceeds 95% RH, and no signs of visible moisture are present, Mohawk FlexLok tabs are an approved
installation method. For thorough guidelines regarding site conditions, floor prep and installation consult the complete
set of FlexLok installation instructions.
The alkalinity or pH in a concrete slab must be tested by the current version of ASTM F710 for a glue-down installation. If pH
exceeds 12, consult Mohawk Group Technical Services at 800.833.6954
Ecoflex AIR and EcoFlex ONE
The following applies to new pour concrete and renovation:
On or Below Grade:
An ASTM E-1745, Class B minimum vapor barrier must be in place and directly in contact with the concrete
No pH or RH testing required when using Mohawk Group approved adhesive or Flexlok+ tabs and the following –
No Sign of visible moisture
Slab is older than 30 days
Above Grade:
No pH or RH testing required when using Mohawk Group approved adhesive or Flexlok+ tabs and the following –
No Sign of visible moisture
Slab is older than 30 days