Welcome Thank you for selecting MOI SWELL as your trusted dehumidifier provider! At MOI SWELL, we take pride in offering premium commercial and industrial dehumidifiers, available in both vertical and horizontal orientations. Our dehumidifiers are designed to swiftly reduce humidity levels, making them ideal for a wide range of applications, including excess water removal, rapid construction drying, and water damage restoration.
BEFORE FIRST USE: Please leave the dehumidifier to stand outside the packaging for 24 HOURS before connecting 0 power, The dehumidifiers may have bean toted or placed upside down during shipping, Leave the dehumidifier to stand upright for 24 hours so the ofl in the compressor can settle from the move, nwt doing so can affect the performance or lifespan of the dehumidifier.
CONTENTS ‘Naming For Using R32 Refrigerant | Parts Identification n Operation Instructions 12 1. Position Your Dehumidifier 12 2. Set Up the Drainage 13 3. Plug in Electrical Cord 13 4. Understand the Control Panel 14 5. General Operation Instructions. 15 6. Timer Setting. 16 7. Smart Functions. 16 Maintenance 17 1. Cleaning the Dehumidifier 17 2. Cleaning the Air Filter 17 Trouble Shooting Guide 18 Parts List 20 1. Parts List 20 2.
WARNING for Using R32 Refrigerant: Transportation, marking and storage for units that employ flammable refrigerants 1. General The following information is provided for units that employ FLAMMABLE REFRIGERANTS. 2. Transport of equipment containing flammable refrigerants Attention is drawn to the fact that additional transportation regulations may exist with respect to equipment containing flammable gas.
Qualification of workers The manual shall contain specific information about the required qualification of the working personnel for maintenance, service and repair operations. Every working procedure that affects safety means shall only be carried out by competent persons. Examples for such working procedures are: « breaking into the refrigerating circuit; + opening of sealed components; Competence of service personnel 1.
a) Commissioning * Ensure that the floor area is sufficient for the REFRIGERANT CHARGE or that the ventilation duct is assembled in a correct manner. + Connect the pipes and carry out a leak test before charging with refrigerant. « Check safety equipment before putting into service. b} Maintenance « Portable equipment shall be repaired outside or in a workshop specially equipped for servicing units with FLAMMABLE REFRIGERANTS. + Ensure sufficient ventilation at the repair place.
« Remove the refrigerant. If the recovery is not required by national regulations, drain the refrigerant to the outside. Take care that the drained refrigerant will not cause any danger. In doubt one person should guard the outlet. Take special care that drained refrigerant will not float back into the building. + When flammable refrigerants are used, --evacuate the refrigerant circuit. --purge the refrigerant circuit with oxygen free nitrogen. --evacuate again.
= Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible. « Discharge capacitors in a way that won't cause any spark. The standard procedure to short circuit the capacitor terminals usually creates sparks. « Reassemble sealed enclosures accurately. If seals are wom, replace them. + Check safety equipment before putting into service.
8. Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. 9.
11. Repairs to sealed components 1) During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to wam of a potentially hazardous situation. 2)Sealed electrical components shall be replaced. 12.
The following procedure shall be adhered to: --safely remove refrigerant following local and national regulations; --purge the circuit with inert gas(optional for A2L); for A2L); -continuously flush or purge with inert gas when using flame to open circuit ;and --open the circuit . The refrigerant charge shall be recovered into the correct recovery cylinders if venting is not allowed by local and national codes.
©) Before attempting the procedure, ensure that: « Mechanical handling equipment is available, if required, for handling refrigerant cylinders; = All personal protective equipment is available and being used correctly; « The recovery process is supervised at all times by a competent person; * Recovery equipment and cylinders conform to the appropriate standards. d} Pump down refrigerant system, if possible.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant, The compressor body shall not be heated by an open flame or other ignition sources to accelerate this process. When oil is drained from a system, it shall be carried out safely. General Safety Instruction 1. The appliance is for indoor use only. 2.
PARTS IDENTIFICATION Control Panel Air Outlet Access door Gravity Drain Outlet Remote Control Port Pump Drain Outlet Power Cord Port Handle Hand Screw Air Inlet Adjustable Foot MOTE: DO NOT OBSTRUCT THE AIR INLET AND/OR OUTLET.
OPERATION INSTRUCTIONS « 1. Position Your Dehumidifier @ Install the dehumidifier horizontally to minimize vibration and or noise, @® You can adjust the feet to level the dehumidifier. To adjust the feet, @® Turn the nut in a clockwise direction to get the nut loosen; @® Turn the foot in a clockwise direction to get the foot down or tum the footing counterclockwise direction to get the foot up; ® Turn the nut in a counterclockwise direction to fix the foot.
2. Set Up the Drainage {1) Drain by Internal Pump The dehumidifier has an internal pump that helps to drain the condensation water freely. When using the pump feature, + The Gravity Drain Outlet needs to be sealed by the included stopper; = Connect the drain hose to the Pump Drain Outlet; * Place the unattached end of the hose in a sink, bucket, pump sump, or out of a window anywhere that water can drain out safely.
4. Understand the Control Panel The control panel of the dehumidifier features a user-friendly interface with 4 buttons and an LED screen. Press the POWER Button to turn the dehumidifier on. After turning on the dehumidifier, the LED screen will display the readouts. Up Power/Purge LED Display Down Timing HH. is humidity percentage value. If no operations on the control panel, this number is the humidity readout of the inlet air the dehumidifier detects which is similar to the current room humidity level.
“: Defrosting icon: It illuminates when the dehumidifier detects frost on the interior. During defrosting, the fan operates while the compressor does not, and the defrost icon flashes until the frost melts. The dehumidifier will automatically begin to dehumidify and the “Defrost” icon will disappear once the defrosting process is complete. Note: Frequent defrosting indicates that the room temperature is too low. It is recommended to add heat when the room temperature is lower than 60°F for proper drying.
6, Timer Setting It enables you to either delay the auto-on or auto-off function of the dehumidifier from 1 to 24 hours, -Set AUTO-ON: When the dehumidifier is off, press the Timer button to set a desired time it begins to work. -Set the dehumidifier AUTO-OFF: When the dehumidifier is on, press the Timer button to set a desired time it shuts off. Set the TIMER by the Below Steps 1. Press the Timer Button and the Timer icon and value . lights up and flashes. 2.
MAINTENANCE To avoid possible electric shock, ensure to turn the dehumidifier off and disconnect the plug from the power source before performing any cleaning or maintenance. 1. Cleaning the Dehumidifier Clean the dehumidifier housing with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the dehumidifier. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners.
Trouble Shooting Guide Below chart will help you solve common problems may occur.
room humidity) Problem Possible Cause Solution Set the target humidity percentage value at 10RH%, Humidity reading the dehumidifier works ] remains at 10RH%, Humid fail normally, which means this ( far from the actual tumidity sensor failure failure does not affect the function of this dehumidifier. Repair and replace the humidity sensor.
Parts List 1. Parts List Picture Description Quantity ) Air Outlet Duct Collar (Pack behind the Access Door) 1 pcs Drain Hose 1 pes ala M4 Screws (to install outlet duct collar) PCs Xx Drain pipes Fastening Rings 1 pes 2. Install the Outlet Duct Collar A Bake sure your dehumidifier is turned off and unplugged before the following operations: Unscrew the 2 screws on the access @ Remove the access door, take the door with a Phillips screwdriver. duct collar out. Access Access door door Air outlet collar ~F.
WARRANTY MOI SWELL warrants to the original purchaser that this MOI SWELL product is free from manufacturing defects in material or workmanship for the limited warranty period of: 2 Years Full Warranty (1 year standard + 1 year with registration) This warranty starts from the date of purchase and covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship.