Welcome Thank you for selecting MOI SWELL as your trusted dehumidifier provider! At MOI SWELL, we take pride in offering premium commercial and industrial dehumidifiers, available in both vertical and horizontal orientations. Our dehumidifiers are designed to swiftly reduce humidity levels, making them ideal for a wide range of applications, including excess water removal, rapid construction drying, and water damage restoration.
BEFORE FIRST USE: Please leave the dehumidifier sitting outside the box for 24 HOURS before plugging it in. The dehumidifiers may have been tutted or placed upside down during shipping.
CONTENTS ‘Warning For Using R32 Refrigerant mannishness 1 Parts Identification 10 Operation Instructions n 1. Position Your Dehumidifier n 2 Set Up the Drainage 12 3. Plug in Electrical Cord 12 4, Understand the Control Panel 5. General Operation Instructions 6. Timer Setting. 15 7. Smart Functions. 15 Maintenance 16 1. Cleaning the Dehumidifier 16 2 Cleaning the Air Filter 16 Trouble Shooting Guide 17 1. Emor Codes 17 2.
Transportation, marking and storage for units that employ flammable refrigerants 1. General The following information is provided for units that employ FLAMMABLE REFRIGERANTS. 2, Transport of equipment containing flammable refrigerants Attention is drawn to the fact that additional transportation regulations may exist with respect to equipment containing flammable gas.
Qualification of workers The manual shall contain specific information about the required qualification of the working personnel for maintenance, service and repair operations. Every working procedure that affects safety means shall only be carried out by competent persons. Examples for such working procedures are: « breaking into the refrigerating circuit; « opening of sealed components; Competence of service personnel 1.
a)Commissioning « Ensure that the floor area is sufficient for the REFRIGERANT CHARGE or that the ventilation duct is assembled in a correct manner. + Connect the pipes and carry out a leak test before charging with refrigerant. + Check safety equipment before putting into service. b) Maintenance + Portable equipment shall be repaired outside or in a workshop specially equipped for servicing units with FLAMMABLE REFRIGERANTS, =» Ensure sufficient ventilation at the repair place.
-purge the refrigerant circuit with oxygen free nitrogen. -evacuate again. {hot required for A2L refrigerants); -cut out the compressor and drain the oil. Information on servicing 1. General The manual shall contain specific information for service personnel according. 2, Checks to the area Prior to beginning work on systems containing FLAMMABLE REFRIGERANTS, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the REFRIGERATING SYSTEM 3.
« Ensure sufficient ventilation at the repair place. « Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible. « Discharge capacitors in a way that won't cause any spark. « When brazing is required, the following procedures shall be carried out in the following order: -Safely remove the refrigerant following local and national regulations. If the recovery is not required by national regulations, drain the refrigerant to the outside.
--The ventilation machinery and outlets are operating adequately and are not obstructed; --If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; --Marking to the equipment continues to be visible and legible.
Electronic leak detectors may be used to detect refrigerant leaks but, in the case of FLAMMABLE REFRIGERANTS, the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
» Label the system when charging is complete (if not already). + Extreme care shall be taken not to overfill the REFRIGERATING SYSTEM. Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. 17.
Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i. e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
Parts Identification Control Panel Filter Gravity Drain Outlet Pump Drain Outlet Remote Control Port Power Cord Port Air Outlet A, Air Inlet Control Cabinet ~~ Adjustable Foot MOTE: DO NOT OBSTRUCT THE AIR INLET AND FOR OUTLET.
OPERATION INSTRUCTIONS * 1. Position Your Dehumidifier + Make sure to install the dehumidifier experimentally to minimize vibration and/or noise. Importantly, prevents water leakage. + You can adjust the feet to level the dehumidifier. To adjust the feet, + Tum the nut in a clockwise direction to get the nut loosen; » Tum the foot in a clockwise direction to get the foot down or turn the foot in a counterclockwise direction to get the foot up; » Tum the nut in a counterclockwise direction to fix the foot.
2, Set Up the Drainage (1) Drain by Internal Pump The dehumidifier has an internal pump that helps to drain the condensation water freely. When using the pump feature, + The Gravity Drain Outlet needs to be sealed by the included stopper; + Connect the drain hose to the Pump Drain Outlet; » Place the unattached end of the hose in a sink, bucket, pump sump, or out of a window anywhere that water can drain out safely.
4. Understand the Control Panel The control panel of the dehumidifier features a user-friendly interface with 4 buttons and an LED screen. Press the POWER Button to tum the dehumidifier on. After muting on the dehumidifier, the LED screen will display the readouts. Up Power/Purge LED Display Down Timing HR. is humidity percentage value. If no operations on the control panel, this number is the humidity readout of the inlet air the guide r detects which is similar to the current room humidity level.
#% Defrosting icon: It illuminates when the dehumidifier detects frost on the interior. During defrosting, the fan operates while the compressor does not, and the defrost icon flashes until the frost melts. The dehumidifier will automatically begin to dehumidify and the “Defrost” icon will disappear once the defrosting process is complete, Note: Frequent defrosting indicates that the room temperature is too low. It is recommended to add heat when the room temperature is lower than 60°F for proper drying.
6. Timer Setting It enables you to either delay the auto-on or auto-off function of the dehumidifier from 1 to 24 hours. Set AUTO-ON: When the dehumidifier is off, press the Timer button to set a desired time it begins to work. Set the dehumidifier AUTO-OFF: When the dehumidifier is on, press the Timer button to seat desired time it shuts off. Set the TIMER by the Below Steps 1. Press the Timer Button and the Timer icon and value ©. lights up and flashes. 2.
Maintenance To avoid possible electric shock, ensure to tum the dehumidifier off and disconnect the plug from the power source before performing any cleaning or maintenance. 1. Cleaning the Dehumidifier Clean the dehumidifier housing with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the dehumidifier. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners.
Trouble Shooting Guide 1. Error Codes Number | Error Code Name's of The Fault Display information transmission abnormal When "Ec" error occurs, the control panel becomes unresponsive and the dehumidifier stops working. To resolve this issue: + Press any button to clear the alarm. + Tum off the dehumidifier and unplug it to inspect for any obstructions. + Wait for 10 minutes before restarting the dehumidifier.
2. Trouble Shooting Chart The below chart will help you solve common problems that may occur. If the problem you come across can hot be fixed after troubleshooting or the problem is not listed in the below troubleshooting chart, please contact MOI SWELL customer service to obtain professional support.
WARRANTY MOI SWELL warrants to the original purchaser that this MOI SWELL product is free from manufacturing defects in material or workmanship for the limited warranty period of: 2 Years Full Warranty (1 year standard 1 year with registration) This warranty starts from the date of purchase and covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship.