For drywall/plaster fastening, 1/8 Molly or Toggle bolts must be used.
The recommended mounting procedure is:
1. For drywall mounts, "Molly Bolts" are preferred. Alternatively, toggle bolts are a suitable option, as
they offer a pull-down force more than 4X the industry standard, and are highly recommended in
areas prone to seismic activity.
2. Alternatively for drywall mounts, Bugle-head #6 Drywall screws (coarse thread) are also acceptable, if
all 4 tie-down points are used, offering an industry standard of a pull-down strength of at least 4X the
weight of the unit.
3. If the wall thickness is at least 1/2" wood (plywood, for example), nails can also be used.
Cables must be properly dressed and supported. Both AC and DC cables should be routed with a service
loop and must be supported at least once within 18” of the power supply unit. Cables can be run in
conduit, providing (a) the conduit is not hanging on the cables, (b) the service loop exists, and (c) there is
at least one support/tie-down on the cables between conduit and power supply.