User's Manual

STAR 3000 Installation Manual
Mojix Incorporated
www.mojix.com
(877) 886-6549
Page
26
of
45
Confidential and Proprietary
Figure 19: Zone Configuration page
Configuration Item Description
Name The name of the Zone (unique name are required)
X Pos The X coordinate relative position of the zone
Y Pos The Y relative position of the zone
Z Pos The Z relative position of the zone.
Type Configures the operation of the Zone, please refer to Zone
Type Descriptions in Table 6
Mode Configures the mode of operation for the Zone (only
applicable in DDD Zone types). Refer to Zone Mode
Descriptions in Table 7 for mode descriptions.
Source Configures the source of the sensor events that may trigger
the activation of the zone. Refer to Zone Source
Descriptions in Table 8 for source descriptions.
Power Div Configures the zone to use a power diversity profile
specified by the label that is defined in the Power Diversity
Configuration page.
Use If selected this indicates to the Mojix system that this Zone
is available for operation.
Del If selected this row will be deleted on “Save”
Table 5: Zone Configuration
Configuration Item Description
DDD Identifies this zone as a Dock Door zone. Objects moving
through this zone will be processed by the DDD application
Location I Identifies this zone as a Location zone. Objects moving
through this zone will be processed by the Location
application. This zone will be but into the background if
any sensor is tripped.
Location II Same as "Location I" but the group does not go into the
background ever (always on).