User's Manual

STAR 3000 Installation Manual
Mojix Incorporated
www.mojix.com
(877) 886-6549
Page
27
of
45
Confidential and Proprietary
Table 6: Zone Type Descriptions
Configuration Item Description
Shipping This indicates to the system that all events that are
triggered by this zone will be leaving the coverage area.
Receiving This indicates to the system that all events that are
triggered by this zone are product that will be entering the
coverage area.
Bidirectional This indicates to the system that events that are triggered
by this zone are product that will be entering or leaving the
coverage area.
None Used for Location zones
Table 7: Zone Mode Descriptions
Configuration Item Description
Internal This indicates to the Mojix system that sensor events that
trigger zone activation will be from internal Mojix sensors.
External This indication to the Mojix system that sensor events that
trigger zone activation will be received externally from the
Mojix system through the ALE logical reader interface.
None Used for Location zones
Table 8: Zone Source Descriptions
Power Diversity Configuration
The Power Diversity configuration page is used to configure a power profile that can be selected on the
Zone configuration page. The power profiles are used in conjunction with the Location application to
provide greater accuracy.
Figure 20: Power Diversity Configuration page
Configuration Item Description