User's Manual

20
eMux Specification Comment
RF input connector TNC connector
RF output connector – 1 TNC connector
RF output connector – 2 TNC connector
RF output connector – 3 TNC connector
RF output connector – 4 TNC connector
Calibration Pin See eMux Calibration (Section 7)
Power supply connector External power supply
Table 7: eMux Cabling Specification
Figure 18: eMux Physical Diagram
Mojix eNode Multiplexer Specifications
Parameter Specification
Signals Present at Input/Output DC, RF and Control
RF Frequency Range 902-928 MHz
RF Signal Level (Max.) +20 dBm (output)
Input Connector TNC
Output Connector 4 TNC’s
Input Impedance 50 Ohm
DC Input 24 V
DC Input Connector Male Power Jack
Table 8: eMux Operating Specification
Additional information about eMux calibration can be found in Section 6.3: eMux Calibration. However this step should
be done after initially setting up all system components.