User Manual

7940
P100 Filter Disk
7950
P100 plus Nuisance
OV/AG Filter Disk
7920
Piggyback Adapter
Moldex, Ideas that wear well and the PVC-Free
logo are registered trademarks.
9900-046 REV D 5/15
7100
Organic Vapor
Cartridge
7400
Ammonia/
Methylamine
Cartridge
7500
Formaldehyde
Cartridge
7990
P100 Filter Cartridge
7960
P100 plus Nuisance
OV Filter Disk
8910 N95 Pre-Filter
8970 R95 Pre-Filter
Adjust head cradle then pull the cradle to
the top of the head so it rests on the crown.
Open valve cover by pulling up on the latch.
Pull the straps out from underneath the tabs
of the strap channel. Close and snap shut
the valve cover.
Attach the bottom straps directly against
the back of your neck.
Positive Pressure Seal Check: Cover
the exhalation valve vent without pressing
too hard against face, and exhale gently to
create a slight positive pressure. If air
leakage is detected, re-adjust the position
of the facepiece and the tension of both
headstraps and repeat the seal check until
leakage is eliminated.
Tighten top straps first then the lower neck
straps until you have a very snug and
leak-free fit. Facepiece should not be loose
or slide up or down the nose. Tighten by
pulling on ends or loosen by pushing out on
buckle tab. Do not overtighten. Further
tighten top straps if necessary.
DROP DOWN MODE
PERFORM A NEGATIVE OR POSITIVE SEAL CHECK EACH
TIME BEFORE ENTERING A CONTAMINATED AREA.
®
First adjust head cradle then place respirator
under the chin and pull the cradle to the top
of the head so it rests on the crown.
Attach the bottom straps directly against
the back of the neck.
To lock the straps in position, open the valve
cover by pulling up on the latch. Position
straps underneath the tabs of the strap
channel. Close and snap shut the valve cover.
Negative Pressure Seal Check: Cover
both cartridges without pressing too hard
against face, and gently inhale and hold
your breath. The facepiece should slightly
collapse. If air leakage is detected, re-adjust
the position of the facepiece and the tension
of both headstraps and repeat the seal
check until leakage is eliminated.
Tighten top straps first then the lower neck
straps until you have a very snug and
leak-free fit. Facepiece should not be loose
or slide up or down the nose. Tighten by
pulling on ends or loosen by pushing out on
buckle tab. Do not overtighten. Further
tighten top straps if necessary.
STANDARD LOCK DOWN MODE
7200
Acid Gas Cartridge
Chlorine/Hydrogen Chloride/Sulfur
Dioxide/or Chlorine Dioxide/or Hydrogen
Flouride/or Hydrogen Sulfide.
7300
Organic Vapor/
Acid Gas Cartridge
Organic Vapors/Chlorine/Hydrogen
Chloride/Sulfur Dioxide/Or Chlorine
Dioxide/Or Hydrogen Fluoride/
Or Hydrogen Sulfide.
7600
Multi-Gas/Vapor Smart
®
Cartridge
Organic Vapors/Ammonia/Methylamine/
Chlorine/Hydrogen Chloride/Sulfur
Dioxide/Or Chlorine Dioxide/
Or Hydrogen Fluoride/
Or Formaldehyde/Or Hydrogen Sulfide.
CARTRIDGES & FILTERS
7000/7800 HALF MASKS AND 9000 FULL FACE MASK FITTING INSTRUCTIONS
7000/7800/9000 ACCESSORIES AND REPLACEMENT PARTS
Grab lower lengths of head harness with
each hand, just above each adjustment
buckle, and while positioning chin in flange,
pull harness over the head.
Push facepiece onto face and chin with one
hand and position for most comfortable and
secure seal while pulling and tightening
neck tab of harness with other hand. Repeat
for other neck tab. For easiest, most secure
and best fit, always adjust neck harness
tabs first before tightening top harness tabs.
Positive Pressure Seal Check: Cover the
exhalation valve vent without pressing too
hard against face, then exhale gently to
create a slight positive pressure. If air
leakage is detected, re-adjust the position
of the facepiece and the tension of head
harness and repeat the seal check until
leakage is eliminated.
Negative Pressure Seal Check: Cover
both cartridges without pressing too hard
against face, then gently inhale and hold your
breath. The facepiece should slightly
collapse. If air leakage is detected, re-adjust
the position of the facepiece and the tension
of head harness and repeat the seal check
until leakage is eliminated.
PERFORM BOTH NEGATIVE
AND POSITIVE SEAL CHECKS
EACH TIME BEFORE ENTERING
A CONTAMINATED AREA.
WARNING: Before using these respirators, you must read manual for complete instructions. If you cannot obtain a proper fit, do not enter the contaminated area and see your supervisor.
Follow all instruction and warnings on the use of this respirator and wear at all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in
sickness or death. For additional information, consult your Supervisor, read all information on box and phone +1 (800) 421-0668 or +1 (310) 837-6500 ext. 512/550. www.moldex.com
7020
Pre-Filter Retainer
7001/7801/9001 Facepiece, Small
7002/7802/9002 Facepiece, Medium
7003/7803/9003 Facepiece, Large
9000 Replacement Parts:
0073 Diaphragm Kit
0074 Gasket Kit
0092 Head Harness
0093 Face Shield Protectors
0094 Med./Large Nose Cup Assembly
0095 Small Nose Cup Assembly
0098 Spectacle Kit
7000 Replacement Parts:
0072 Head Harness Assembly
0073 Diaphragm Kit
0074 Gasket Kit
7140 Organic Vapor
Cartridge/
P100 Cartridge Disk
7640 Multi-Gas/Vapor
Smart
®
Cartridge/
P100 Cartridge Disk
7999
Splash/Spark Protector
REUSABLE RESPIRATORS
FITTING INSTRUCTIONS AND
SELECTION GUIDE
7000/7800/9000