SEALED RECEPTACLE ASSEMBLY - SERVICEABILITY
Installation
1) Return TPA to pre-lock position
- Carefully insert a standard screw driver into slot on top of TPA.
- Carefully pry TPA forward and listen for audible click.
- TPA is now in pre-lock position.
2) Release terminal from connector assembly
- Insert and drive forward extractor tool to release terminal.
- Pull terminal from rear of connector.
SEALED BLADE ASSEMBLY - SERVICEABILITY
TERMINAL INSTALLATION
Screw Driver Slot
Terminal Release
Service Hole
Service Tool
1) Return TPA to pre-lock position
- Use standard needle nose pliers to return TPA to pre-lock position.
- Insert needle nose pliers into service hole and carefully pull TPA.
- Listen for loud audible click.
- TPA is now in pre-lock position.
2) Release terminal from connector assembly
- Insert and drive forward extractor tool to release terminal.
- Pull terminal from rear of connector.
Needle Nose Pliers
Service Holes
Terminal Release
Service Hole
Extractor Tool
Assure housing TPA is in pre-lock position. Align
polarization feature on terminal with keyway in seal cap.
Insert terminal and push until seated. Push receptacle TPA
back to locked position. Plug TPA will return to locked
position when mated with receptacle housing.
90° Mis-oriented Terminal 180° Mis-oriented Terminal
Correctly oriented Terminal
Polarization feature
Service Tool
Order No. 63813-1500