Operation Manual
HD-TVI DVR User Manual
30
Fig 4-31 P.T.Z Configuration-Serial Port
② Select “Enable” and set up the value of address, baud rate and protocol according to the
settings of the speed dome.
③ Select “All” to set the same settings for all channels.
Advanced settings include preset setting, cruise setting and track setting.
Go to MenuSetup P.T.Z Advanced. Refer to Fig 4-32.
Fig 4-32 P.T.Z configuration-advanced
To set up preset:
Parameter
Meaning
Address
The address of the PTZ device.
Baud rate
Baud rate of the PTZ device. Range form: 110, 300, 600, 1200, 2400,
4800, 9600, 19200, 34800, 57600, 115200, 230400, 460800, 921600.
Protocol
Communication protocol of the PTZ device. Range from: NULL,
PELCOP, PELCOD, LILIN, MINKING, NEON, STAR, VIDO, DSCP,
VISCA, SAMSUNG, RM110, HY, N-control.
Simulative
Cruise
If enabled, no matter whether the PTZ device supports cruise or not, the
presets will cruise.