Printer User Manual

The internal symbol set is used.
Defining Bar Code Fields
Each bar code field requires a separate definition.
Syntax
B,field#,# of char,fix/var,row,column,
font,density,height,text,alignment,
field rot p
B1. B Bar Code Field.
B2. field# Unique number from
0-999
(
0-99
for 9403) to identify this field.
B3. # of char Maximum number of characters. If the bar code uses a check
digit, allow an extra character for the check digit. The actual
maximum number of characters is limited by the size of the
label and bar code density. Range:
0-2710
(
0-100
for 9403).
Data Matrix can use up to 2710 numeric characters or 2335
alphanumeric characters. Quick Response (QR Code) can
use 299-2710 characters. See Appendix A, "Samples" for
more information.
B4. fix/var Fixed (
F
) or variable (
V
) length field.
Bar Code Number of Characters Fixed or
Variable
UPCA
12 F
UPCA+2
14 F
UPCA+5
17 F
UPCA+Price CD
12 F
UPCE
7F
UPCE+2
9F
UPCE+5
12 F
EAN8
8F
EAN8+2
10 F
EAN8+5
13 F
EAN13
13 F
EAN13+2
15 F
EAN13+5
18 F
EAN13+Price CD
13 F
POSTNET
9 or 11 F
3-8
Defining Fields