MONARCH INSTRUMENT Instruction Manual Monarch 314 Datalogging Humidity Temperature Meter © Monarch Instrument 2002 all rights reserved 1071-8041-210 15 Columbia Drive Amherst, NH 03031-2334 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com Website: www.monarchinstrument.
Safeguards and Precautions 1. Read and follow all instructions in this manual carefully, and retain this manual for future reference. 2. Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated. 3. Do not touch or manipulate the sensor. 4. Do not expose the sensor to direct light. This may cause false readings. 5. Do not expose the sensor to static electricity. 6.
MODEL 314 DATALOGGING HUMIDITY TEMPERATURE METER DECLARATION OF CONFORMITY Table of Contents Section Monarch Instrument Page Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA 1.0 Introduction .................................................................................................................1 declares that the product: 2.0 Specifications ............................................................................................................1 3.
MODEL 314 DATALOGGING HUMIDITY TEMPERATURE METER 1.0 Introduction This instrument is a dual channel, recording digital Humidity / Temperature meter providing simultaneous display of ambient humidity and temperature on the first channel, and a wide range temperature only measurement on the second channel. The first channel incorporates a polymer capacitive humidity sensor and a semiconductor temperature sensor (T1) in a detachable probe.
Notes MODEL 314 DATALOGGING HUMIDITY TEMPERATURE METER Symbol Definitions and Feature Locations: : Low battery indication. Battery voltage is not sufficient for proper operation. : Indicates ‘Auto Power Off’ is enabled : Indicates that the display data is being held MAX : The Maximum value is now being displayed MIN : The Minimum value is now being displayed REC : Indicates that the instrument is recording. When flashing, the memory is full.
MODEL 314 DATALOGGING HUMIDITY TEMPERATURE METER 4.0 Operating Instructions: 4.1 Preparation for Measurement Measurement of ambient humidity and temperature (T1) may be made with the probe clipped to the instrument or hand held remotely. For measurement of a second temperature, plug a Type K thermocouple into the socket marked T2, taking care to observe the polarity of the thermocouple pins. 4.2 Power Press the button to turn the thermometer ON or OFF.
MODEL 314 DATALOGGING HUMIDITY TEMPERATURE METER 6.0 Setup TestLink Software: (Humidity DataLogger) - RS232 Interface The TestLink package contains: 1. Two 3.5” diskettes 2. Custom designed RS232 cable for TestLink System Requirements: Windows 95, Windows 98 or Windows NT 4.0 Minimum Hardware Required: x 486-100 MHz PC, 16 MB RAM x At least 5 MB hard disk space available to install TestLink program x Recommended display resolution is 800x600. Install TestLink: 1.
MODEL 314 DATALOGGING HUMIDITY TEMPERATURE METER Appendix: Thermocouple Probe Specifications Model Range Tolerances Description TP-K01 Wire probe -50°C to 200°C -58°F to 392°F ±2.2°C or ±0.75% ±3.6°F or ±0.75% Teflon insulation. Maximum insulation temperature: 260°C (500°F) TP-K01: Probe for general condition measurements, especially for complex and hard to reach places. 5.0 Calibration Procedure 5.1 Humidity Calibration 1. Turn the unit off. Press and hold the MAX MIN, HOLD and REC buttons.