Use proper gas type for the replace you are installing. If you have conicting gas type, do not install
replace. See dealer where you purchased the replace for proper replace for your gas type or
conversion kit.



 



 

     
     


Before installing replace and burner system, make sure you have the items listed below.
External regulator Piping (check local codes) Sealant (resistant to propane/LP gas)
(supplied by installer) Equipment shutoff valve* Test gauge connection*
Sediment trap (recommended) Tee joint Pipe wrench
approved exible gas line with gas connector (if allowed by local codes — not provided)
* A CSA design-certied equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge
connection. Purchase the CSA design-certied equipment shutoff valve from your dealer.
For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce
incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not
reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent
pointing down as shown in Figure 30. Pointing the vent down protects it from freezing rain or sleet.
FP1977
external regulator
Figure 30 -
External Regulator with Vent Pointing Down
(Propane/LP Only)
FP1977
External
Regulator
100 lb. (min)
Propane/LP
Supply Tank
Vent Pointing
Down








     

When using copper or ex connectors use only ttings
approved for gas connections. The gas control inlet is
3/8" NPT.