Operating instructions

6 14D9999
14D9999 7
PROPANE / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" W.C.
MANUAL / T-STAT PRESSURE MILLIVOLT PRESSURE
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c. Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c. Minimum 11" w.c.
NATURAL GAS
Note: An external regulator is required to reduce supply pressure to a maximum of 10
1
/2 W.C. (11" W.C.
for HI/LO) on natural gas systems operating at higher pressure.
MANUAL / T-STAT PRESSURE MILLIVOLT PRESSURE
Regulator Pressure Setting: 3" w.c. Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Maximum 10
1
/2" w. c. Gas Inlet Pressure: Max. 10
1
/2" w. c.
Minimum 5" w.c. Min. 5" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
LOW - Minimum gas rate — front burner provides a realistic glow on the center log.
HI - Maximum gas rate — front burner provides a realistic glow on the center log, plus the rear burner pro-
vides a pleasing yellow ame.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DLX18PM Manual 22,000 14,000
DLX24/28PM Manual 33,000 19,000
DLX18PT T-Stat 26,000 16,000
DLX24/28PT T-Stat 28,000 20,000
DLX18PV Milli-Volt 22,000 17,000
DLX24/28PV Milli-Volt 33,000 22,000
PRODUCT FEATURES AND SPECIFICATIONS
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DLX18NM Manual 26,000 16,000
DLX24/28NM Manual 32,000 19,000
DLX18NT T-Stat 26,000 16,000
DLX24/28NT T-Stat 26,000 20,000
DLX18NV Milli-Volt 26,000 17,000
DLX24/28NV Milli-Volt 32,000 22,000