User Manual

73D0024
11
KHLDV Series Gas Fireplace

Consult local building codes before beginning the
installation. The installer must make sure to select the
proper vent system for installation. Before installing vent
kit, the installer must read this fireplace manual and vent
kit instructions.
Only a qualified installer/service person should install vent-
ing system. The installer must follow these safety rules:
Wear gloves and safety glasses for protection.
Use extreme caution when using ladders or when
on rooftops.
Be aware of electrical wiring locations in walls and
ceilings.
The following actions will void the warranty on your vent-
ing system:
Installation of any damaged venting component.
Unauthorized modification of the venting system.
Installation of any component part not manufactured
or approved by MHS.
Installation other than permitted by these instruc-
tions.


       
          











**1”
FP2131
Vent pipe clearances
**1”
*3”
73”
(1854 mm)

       

 until the flue penetrates the outside wall. 


           

* A minimum of 3" clearance
to the top is required along
horizontal length until flue pipe
penetrates outside wall.
** A minimum 1" clearance
to combustibles permitted all
around flue at outside wall
24" Vertical Rise
Required Before
Horizontal Run
Figure 7 -
Combustible Clearances for Vent Pipe
FP2131