Gas Heater User Manual

1
65D1009
EYF Series Unvented Gas Log Set

MANUAL CONTROL LIGHTING INSTRUCTIONS
1.  Read the safety information.
. Make sure the manual shutoff valve is fully open.
3. This heater is equipped with an ignition device (piezo) which automatically
lights the pilot.
4. Refer to Page 22, Figure 37 for the location of the piezo ignitor and control
knob. Push in gas control knob slightly and turn control knob clockwise
to the OFF position.
 Knob cannot be turned to OFF unless knob is pushed in slightly. Do
not force.
5. Wait 5 minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas  Follow the instructions under “What to Do if You
Smell Gas”, Page 20. If you do not smell gas, go to the next step.
6. From OFF position, push in gas control knob slightly and turn counterclock-
wise to the IGN position. Figure 33. Push in and hold control knob for 5
seconds.
 If you are running the heater for the first time, it will be necessary to
press in the control knob for 30 seconds to allow air to bleed out of the gas
piping.
7. With the control knob pushed in, push and release the piezo ignitor button to
light the ODS pilot. The pilot is located on the left side of the heater, behind
the middle log and in front of the back log. If piezo ignitor does not light the
pilot, refer to “Match Lighting Instructions”, Page 23.
8. Hold the control knob in for an additional 10 seconds to prevent the ODS pilot
from shutting off the gas while the thermocouple is warming up.
9. Release the control knob.
If the knob does not pop out when released, stop and immediately call your
service technician or gas supplier.
If the ODS pilot will not stay lit after several tries, push and turn the gas
control knob clockwise to OFF and wait 15 seconds. Repeat steps 6
through 9.
10. Push in control knob and turn counterclockwise to the HIGH setting. At
this location the control knob will pop out when positioned correctly. The knob
can now be positioned at any position between HIGH and LOW. Figures 34
and 35
Rotate
Push
Figure 33 -
IGN Position
Figure 34 -
HIGH Position
Rotate
Push
Figure 35 -
LOW Position
Rotate

     
      

1. Turn control knob clockwise to position to completely shut off the heater.
. If applicable: Turn off all electric power to the heater.
TO TURN OFF GAS TO HEATER