Gas Heater User Manual

65D1009
4
EYF Series Unvented Gas Log Set

16. Keep room area clear and free from combustible
materials, gasoline and other flammable vapors and
liquids.
17. Unvented gas heaters are a supplemental zone heater.
They are not intended to be a primary heating appli-
ance. Water vapor produced by an unvented heater
can create moisture problems in a home when oper-
ated for extended periods of time.
18. During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain
oils, films or bonding agents. These chemicals are not
harmful but may produce annoying smoke and smells
as they are burned off during the initial operation of the
appliance; possibly causing headaches or eye or lung
irritation. This is a normal and temporary occurrence.
The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear
with continued use.
19. Input ratings are shown in BTU per hour and are for
elevations up to ,000 feet. For elevations above ,000
feet, input ratings should be reduced 4 percent for each
1,000 feet above sea level. See the National Fuel Gas
Code.
       
   


        

       

0. The heater and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures
in excess of 1/ psig (3.5 kPa).
1. The heater must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/ psig
(3.5 kPa).
. Do not use this room heater if any part has been under
water. Immediately call a qualified service technician
to inspect the room heater and to replace any part of
the control system and any gas control which has been
under water.
3. This appliance must not be used with glass doors in
the closed position. This can lead to pilot outages and
severe sooting outside the fireplace.
4. Never burn solid fuels in a fireplace where a unvented
room heater is installed.
5. Always have a fireplace screen in place when the ap-
pliance is in operation and , unless other provisions for
combustion air are provided, the screen shall have an
opening(s) for induction of combustion air.

Never connect unit to private (non-utility)
gas wells. This gas is commonly known
as wellhead gas.




Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE
ANSI Z3.1 or NFPA54 which can be obtained from…

1430 Broadway
New York, NY 10018
or

Batterymarch Park
Quincy, MA 069