FLAME APPEARANCE
Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.
In addition, periodically check the flames visually during operation.
CHECKING THE PILOT FLAME
The pilot flame must always be present when the heater is in operation. It should just touch the top of the
thermocouple tip for natural. Refer to Figures 19 and 21 for correct pilot flame.
If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. Refer to Figures 20 and 22
for incorrect shape of pilot flame.
MILLI-VOLT CONTROL
Figure 19 - Correct Appearance of Pilot Flame
Figure 20 - Incorrect Appearance of Pilot Flame
MANUAL CONTROL
Figure 21 - Correct Appearance of Pilot Flame
Figure 22 - Incorrect Appearance of Pilot Flame
Thermocouple
for Natural
Thermocouple
for LP
Thermocouple
for LP
Thermocouple
for Natural
Thermocouple
for Natural
Thermocouple
for Natural
Thermocouple
for LP
Thermocouple
for LP