Operating instructions

6
39D3200
NATURAL GAS
Manual Pressure Milli-Volt Pressure
Regulator Pressure Setting: 4.0" w.c. Regulator Pressure Setting: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w.c. Pilot Regulator: 3.5" w.c.
Min. 5" w.c. Gas Inlet Pressure: Max. 10 1/2" w. c.
Min. 5" w.c.
PRODUCT FEATURES AND SPECIFICATIONS
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manual Pressure Milli-Volt Pressure
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c. Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c. Minimum 11" w.c.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
YS24/18NM Manual 28,000 15,000
YS24/18NV Milli-Volt 28,000 18,000
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
YS24/18PM Manual 28,000 18,000
YS24/18PV Milli-Volt 28,000 21,000
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN -Valve position to light/maintain a standing pilot.
HI/LOW -Variable position corresponding to desired flame height (heat input)
Milli-Volt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN -Valve position to light/maintain a standing pilot.
ON -Valve position to turn ON/OFF log set with remote switch/thermostat.
HI/LOW -Variable position to control flame height (heat output).
PILOT
The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The milli-volt gas log pilot is fitted with a milli-volt generator to provide power for remote activation.