Ensure that minimum clearances shown in Figures 4
through 8 are maintained. Left and right clearances are
determined when facing the front of the rebox.
Follow these instructions carefully to ensure safe instal-
lation. Failure to follow these requirements may create a
re hazard.
1. The clearance from the inside
of the appliance to any combustible wall should not be
less than 9". Figure 4
. The ceiling must be at least 4”
from the top of the rebox opening. Figure 4
3.   The appliance may be placed
against a combustible back wall.

9"
Minimum
42"
Minimum
9"
Minimum
FP2687
minimum clearances
FP687
Figure 4 -
Clearance and Height Requirements
4. The canopy supplied with the unit
must be installed. If a combustible mantel is installed,
it must meet the clearance requirements as shown in
Figure 5. However, if lower mantel height is desired,
refer to Page 14, Figure 6.
Combustible
Material Can
Contact Top
of Fireplace
FP690
Noncombustible Material
Only if Needed to Cover
Radiant Top Face
Figure 5 -
Mantel Clearances
12”
8”
8”
14”
FP2691
mantel clear wide canopy
FP691
Figure 6 -
Mantel Heights for Wide Prole Canopy
45°
1”
256O
3”
5”
6”
56O
56O
56O
FP2692
mantel leg clearance
6”
756O
756O
9”
Finish Wall
Combustible
Material Area
FP69
Figure 5a -
Mantel Leg Clearance