Gas Log Set Installation
11
NBST27 Unvented Gas Log Set
Monessen • NBST27 Gas Log Set Installation/Owner's Manual • 81D3032 • Rev A • 08/16
SECURE APPLIANCE
PLACE AND SECURE APPLIANCE
1. Centerthegaslogunitinthereplaceorrebox.Make
certain the front feet of the grate sit inside the front
edgeofthereplaceorrebox.
2. Anchor holes are located on the right and left sides of
the unit. After centering the grate correctly, mark the
holelocationsonthereplace/reboxoor.Drilltwo(2)
5/32” diameter holes approximately 1
1
⁄4" deep.
3. Anchortheunittothereplace/reboxoorusingthe
screws provided. Figure 11
Proper installation of the grate is essential to prevent
any movement of the logs and controls during oper-
ation.
NOTE
RIGHT CORNER APPLICATIONS
For right corner installations, the piezo ignitor
can be moved to the opposite corner of the ap-
pliance:
1. Remove wire from back of ignitor.
2. Remove two (2) screws holding piezo brack-
et.
3. Reattach bracket on the opposite corner
(where inlet fuel comes into the valve) by us-
ing two clearance holes on burner base.
4. Reattach wire to ignitor.
Figure 11 -
Secure Burner
FP2375
secure burner
Piezo Ignitor
(Original Location)
The replace and gas logs function as a system. If
the replace is spilling into the room (check with
a match or a smoke stick), reposition the damper
clamp until a positive draft is obtained by opening
the damper. If negative pressure in home prevents
having a positive draft, contact your dealer for
assistance.
WARNING
You must secure the gas log heater to the replace
oor. If not, the entire unit may move when you
adjust the controls. Movement of unit may cause
shifting of the gas logs which leads to sooting and
improper burning. Grate movement could cause a
gas leak.
Special care is required if you are installing the unit
into a sunken replace. You must raise the replace
oor to allow access to gas log controls. This will
insure adequate air ow and guard against sooting.
Raise the fireplace floor using noncombustible
materials, as described in Placement in a Fireplace
with Restrictive Barrier on Page 6.
WARNING