Gas Log Set Installation

18
NBST27 Unvented Gas Log Set
Monessen • NBST27 Gas Log Set Installation/Owner's Manual • 81D3032 • Rev A • 08/16
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner ame patterns. Do
notallowfans toblowdirectly into thereplace. Do not
placeablowerinsidetheburnareaoftherebox.Ceiling
fansmaycreatedraftsthatalteramepatterns.Sooting
and improper burning will result.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
lmsorbondingagents.Thesechemicalsarenotharm-
ful, but may produce annoying smoke and smells as they
are burned off during the initial operation of the appliance,
possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
FOR YOUR SAFETY, READ BEFORE LIGHTING
A. This appliance is equipped with a piezo ignition device which lights the pilot. If piezo is not working properly
see Match Lighting Instructions.
B. BEFOREOPERATINGsmellallaroundtheapplianceareaforgas.Besuretosmellnexttotheoorbecause
somegasisheavierthanairandwillsettleontheoor.
WHAT TO DO IF YOU SMELL GAS:
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
Ifyoucannotreachyourgassupplier,calltheredepartment.
C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn
byhand,don'ttrytorepairit.Callaqualiedservicetechnician.Forceorattemptedrepairmayresultinare
or explosion.
D. Donotusethisapplianceifanypartofithasbeenunderwater.Immediatelycallaqualiedservicetechnician
to inspect the appliance and to replace any part of the control system and any gas control that has been under
water.
FP2373
burner controls
Control Knobs
Piezo Ignitor
Figure 30 -
Burner Controls
The initial break-in operation should last four hours with the
burner at the highest setting. Provide maximum ventilation
by opening windows or doors to allow odors to dissipate.
Any odors remaining after this initial break-in will be slight
and will disappear with continued use.
This appliance must not be used with glass doors in the
closed position. This can lead to pilot outages and severe
sootingoutsidethereplace.
If you do not follow these instruction exactly, a re or explosion may result causing property damage,
personal injury or loss of life.
WARNING