Gas Log Set Installation

9
NBST27 Unvented Gas Log Set
Monessen • NBST27 Gas Log Set Installation/Owner's Manual • 81D3032 • Rev A • 08/16
FLOOR CLEARANCES
The gas log heater must be installed at least 3/4" above
any combustible ooring material, such as carpeting or
tile,whichiscloserthan14"tothebaseofthereplace.
The minimum distance must be maintained from the top
surface of carpeting, tile, etc. Figure 8
OR
Thegaslogheatermaybeinstallednearertotheoorifa
minimum of 14" of noncombustible material such as slate
ormarbleisinstalledbetweenthebaseofthereplaceand
thecombustibleooring.Figure 9
3/4"
FP2368
combustible floor
Combustible
Material
Heater in Fireplace
or Firebox
Figure 8 -
Minimum Clearance above Combustible Flooring
14" Min.
FP2369
comb floor
Heater in Fireplace
or Firebox
Combustible
Material
This distance may now
be less than 3/4"
Figure 9 -
Minimum Clearance above Combustible Flooring with Noncombus-
tible Material Installed at Base of Fireplace